2022Journal of Neural EngineeringOpen access

Optimal design of transcranial magnetic stimulation coil with iron core

Yajie Xu, Junhao Zhang, Siping Xia, Jian Qiu, Jing Qiu, Xiaodong Yang, Weiguo Gu, Yingcong Yu

Open full text 5 citations

Abstract

Abstract Objective . Iron core coils offer a passive way to increase the induced electric field intensity during transcranial magnetic stimulation (TMS), but the influences of core position and dimensions on coil performance have not been elaborately discussed before. Approach. In this study, with the basic figure-of-eight (Fo8) and slinky coil structures, iron core coil optimization is performed with the finite element method considering core position and dimensions. A performance factor combining performance parameters, including the maximum induced electric field, stimulation depth, focus, and heat loss, is utilized to evaluate the comprehensive coil performance. Main results. According to the performance factor, both iron core coils obtain the best overall performance with a fill factor 0.4 and the two legs of the iron core close to the inner sides of the coil. Finally, three prototypes are constructed—the basic, optimized, and full-size slinky iron core coil—and magnetic field detection demonstrates a good agreement with the simulation results. Significance. The proposed systematic optimization approach for iron core coil based on Fo8 and slinky basic structure can be applied to improve TMS coil performance, reduce power requirements, and guide the design of other iron core TMS coils.

Open-access reader

About this research paper

What this paper is about

Abstract Objective . Iron core coils offer a passive way to increase the induced electric field intensity during transcranial magnetic stimulation (TMS), but the influences of core position and dimensions on coil performance have not been elaborately discussed before. Approach. In this study, with the basic figure-of-eight (Fo8) and slinky coil structures, iron core coil optimization is performed with the finite element method considering core position and dimensions. A performance factor combining performance parameters, including the maximum induced electric field, stimulation depth, focus, and heat loss, is utilized to evaluate the comprehensive coil performance. Main results. According to the performance factor, both iron core coils obtain the best overall performance with a fill factor 0.4 and the two legs of the iron core close to the inner sides of the coil. Finally, three prototypes are constructed—the basic, optimized, and full-size slinky iron core coil—and magnetic field detection demonstrates a good agreement with the simulation results. Significance. The proposed systematic optimization approach for iron core coil based on Fo8 and slinky basic structure can be applied to improve TMS coil performance, reduce power requirements, and guide the design of other iron core TMS coils.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Objective . Iron core coils offer a passive way to increase the induced electric field intensity during transcranial magnetic stimulation (TMS), but the influences of core position and dimensions on coil performance have not been elaborately discussed before. Approach. In this study, with the basic figure-of-eight (Fo8) and slinky coil structures, iron core coil optimization is performed with the finite element method considering core position and dimensions. A performance factor combining performance parameters, including the maximum induced electric field, stimulation depth, focus, and heat loss, is utilized to evaluate the comprehensive coil performance. Main results. According to the performance factor, both iron core coils obtain the best overall performance with a fill factor 0.4 and the two legs of the iron core close to the inner sides of the coil. Finally, three prototypes are constructed—the basic, optimized, and full-size slinky iron core coil—and magnetic field detection demonstrates a good agreement with the simulation results. Significance. The proposed systematic optimization approach for iron core coil based on Fo8 and slinky basic structure can be applied to improve TMS coil performance, reduce power requirements, and guide the design of other iron core TMS coils.

Key concepts: Electromagnetic coil, Transcranial magnetic stimulation, Core (optical fiber), Magnetic core, Finite element method, Computer science, Position (finance), Acoustics

Related papers

Back to paper searchBrowse research topicsOriginal source
Optimal design of transcranial magnetic stimulation coil with iron core — Research Paper | ScholarLens