2022Energy Sources Part A Recovery Utilization and Environmental EffectsRequires access

Performance analysis of parabolic trough solar collector under varying optical errors

Belkacem Agagna, Omar Behar, Arezki Smaïli

Open publisher page 8 citations

Abstract

A typical parabolic trough solar field consists of a number of collectors that are made up of two main components: a parabola and a receiver. Various errors arise during the design/manufacturing, installation, and operation phases of the solar field. These errors influence the shape of the parabola as well as the alignment of the receiver. The present article aims to quantify the effect of these errors on the performance of a typical parabolic trough collector (PTC). To do so, a coupled optical-thermal model has been developed. The Monte Carlo Ray Tracing (MCRT) method is used to create and solve the optical model. The latter is then integrated with Computational Fluid Dynamics (CFD) to investigate the PTC’s thermal performance. The losses in performance induced by these errors are quantified. The analysis showed that small errors such as receiver dislocation or tracking error could induce a significant cut in the optical and overall performance. The loss in the optical efficiency due to tracking error of 16 mrad is about 50%. The error in the parabola profile can induce a reduction of 60% in the optical efficiency and up to 80% in the overall efficiency. A 0.05 m dislocation of the receiver can reduce the optical and overall efficiencies by about 37% and 49%, respectively. The results of the present study should support researchers and engineers in defining the optimum acceptable uncertainties through various phases of the design, manufacturing, and installation of the parabolic trough solar field.

About this research paper

What this paper is about

A typical parabolic trough solar field consists of a number of collectors that are made up of two main components: a parabola and a receiver. Various errors arise during the design/manufacturing, installation, and operation phases of the solar field. These errors influence the shape of the parabola as well as the alignment of the receiver. The present article aims to quantify the effect of these errors on the performance of a typical parabolic trough collector (PTC). To do so, a coupled optical-thermal model has been developed. The Monte Carlo Ray Tracing (MCRT) method is used to create and solve the optical model. The latter is then integrated with Computational Fluid Dynamics (CFD) to investigate the PTC’s thermal performance. The losses in performance induced by these errors are quantified. The analysis showed that small errors such as receiver dislocation or tracking error could induce a significant cut in the optical and overall performance. The loss in the optical efficiency due to tracking error of 16 mrad is about 50%. The error in the parabola profile can induce a reduction of 60% in the optical efficiency and up to 80% in the overall efficiency. A 0.05 m dislocation of the receiver can reduce the optical and overall efficiencies by about 37% and 49%, respectively. The results of the present study should support researchers and engineers in defining the optimum acceptable uncertainties through various phases of the design, manufacturing, and installation of the parabolic trough solar field.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A typical parabolic trough solar field consists of a number of collectors that are made up of two main components: a parabola and a receiver. Various errors arise during the design/manufacturing, installation, and operation phases of the solar field. These errors influence the shape of the parabola as well as the alignment of the receiver. The present article aims to quantify the effect of these errors on the performance of a typical parabolic trough collector (PTC). To do so, a coupled optical-thermal model has been developed. The Monte Carlo Ray Tracing (MCRT) method is used to create and solve the optical model. The latter is then integrated with Computational Fluid Dynamics (CFD) to investigate the PTC’s thermal performance. The losses in performance induced by these errors are quantified. The analysis showed that small errors such as receiver dislocation or tracking error could induce a significant cut in the optical and overall performance. The loss in the optical efficiency due to tracking error of 16 mrad is about 50%. The error in the parabola profile can induce a reduction of 60% in the optical efficiency and up to 80% in the overall efficiency. A 0.05 m dislocation of the receiver can reduce the optical and overall efficiencies by about 37% and 49%, respectively. The results of the present study should support researchers and engineers in defining the optimum acceptable uncertainties through various phases of the design, manufacturing, and installation of the parabolic trough solar field.

Key concepts: Parabolic trough, Parabola, Distributed ray tracing, Thermal, Parabolic reflector, Nonimaging optics, Ray tracing (physics), Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance analysis of parabolic trough solar collector under varying optical errors — Research Paper | ScholarLens