2009Faculty Opinions – Post-Publication Peer Review of the Biomedical LiteratureRequires access

Faculty Opinions recommendation of Impact of laryngeal mask airway cuff pressures on the incidence of sore throat in children.

Victor C. Baum

Open publisher page 0 citations

Abstract

BACKGROUND: Hyperinflation of laryngeal mask airway cuffs can cause harm to the upper airway mainly by exerting high pressures on pharyngeal and laryngeal structures thus impairing mucosal perfusion. Although cuff manometers can be used to guide the monitoring of cuff pressures, their use is not routine in many institutions. In a prospective audit, we assessed the incidence of sore throat following day-case-surgery in relation to the intracuff pressure within the laryngeal mask airway.METHODS: Four hundred children (3-21 years) were consecutively included in this study. The laryngeal mask airway was inflated as deemed necessary by the attending anesthetist. Cuff pressures were measured using a calibrated cuff manometer (Portex Limited, Hythe, Kent, UK, 0-120 cm H2O, pressures exceeding the measurement range were set at 140 cm H2O for statistical purposes) at induction of anesthesia.RESULTS: Forty-five children (11.25%) developed sore throat, 32 (8%) sore neck and 17 (4.25%) sore jaw. Of those that developed sore throat, 56.5% had cuff pressures exceeding >100 cm H2O. In contrast, when cuff pressures were <40 cm H2O, there were no episodes of sore throat, whilst there was only a 4.6% occurrence of sore throat if cuff pressures were between 40-60 cm H2O.CONCLUSION: We have demonstrated that intra cuff pressure in laryngeal mask airways is closely related to the development of sore throat with higher pressures increasing its likelihood. Hence, cuff pressures should be measured routinely using a manometer to minimize the incidence of sore throat. PMID: 19281479

About this research paper

What this paper is about

BACKGROUND: Hyperinflation of laryngeal mask airway cuffs can cause harm to the upper airway mainly by exerting high pressures on pharyngeal and laryngeal structures thus impairing mucosal perfusion. Although cuff manometers can be used to guide the monitoring of cuff pressures, their use is not routine in many institutions. In a prospective audit, we assessed the incidence of sore throat following day-case-surgery in relation to the intracuff pressure within the laryngeal mask airway.METHODS: Four hundred children (3-21 years) were consecutively included in this study. The laryngeal mask airway was inflated as deemed necessary by the attending anesthetist. Cuff pressures were measured using a calibrated cuff manometer (Portex Limited, Hythe, Kent, UK, 0-120 cm H2O, pressures exceeding the measurement range were set at 140 cm H2O for statistical purposes) at induction of anesthesia.RESULTS: Forty-five children (11.25%) developed sore throat, 32 (8%) sore neck and 17 (4.25%) sore jaw. Of those that developed sore throat, 56.5% had cuff pressures exceeding >100 cm H2O. In contrast, when cuff pressures were <40 cm H2O, there were no episodes of sore throat, whilst there was only a 4.6% occurrence of sore throat if cuff pressures were between 40-60 cm H2O.CONCLUSION: We have demonstrated that intra cuff pressure in laryngeal mask airways is closely related to the development of sore throat with higher pressures increasing its likelihood. Hence, cuff pressures should be measured routinely using a manometer to minimize the incidence of sore throat. PMID: 19281479

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Hyperinflation of laryngeal mask airway cuffs can cause harm to the upper airway mainly by exerting high pressures on pharyngeal and laryngeal structures thus impairing mucosal perfusion. Although cuff manometers can be used to guide the monitoring of cuff pressures, their use is not routine in many institutions. In a prospective audit, we assessed the incidence of sore throat following day-case-surgery in relation to the intracuff pressure within the laryngeal mask airway.METHODS: Four hundred children (3-21 years) were consecutively included in this study. The laryngeal mask airway was inflated as deemed necessary by the attending anesthetist. Cuff pressures were measured using a calibrated cuff manometer (Portex Limited, Hythe, Kent, UK, 0-120 cm H2O, pressures exceeding the measurement range were set at 140 cm H2O for statistical purposes) at induction of anesthesia.RESULTS: Forty-five children (11.25%) developed sore throat, 32 (8%) sore neck and 17 (4.25%) sore jaw. Of those that developed sore throat, 56.5% had cuff pressures exceeding >100 cm H2O. In contrast, when cuff pressures were <40 cm H2O, there were no episodes of sore throat, whilst there was only a 4.6% occurrence of sore throat if cuff pressures were between 40-60 cm H2O.CONCLUSION: We have demonstrated that intra cuff pressure in laryngeal mask airways is closely related to the development of sore throat with higher pressures increasing its likelihood. Hence, cuff pressures should be measured routinely using a manometer to minimize the incidence of sore throat. PMID: 19281479

Key concepts: Sore throat, Cuff, Medicine, Airway, Anesthesia, Laryngeal mask airway, Throat, Larynx

Related papers

Back to paper searchBrowse research topicsOriginal source
Faculty Opinions recommendation of Impact of laryngeal mask airway cuff pressures on the incidence of sore throat in children. — Research Paper | ScholarLens