Field calibration for multidirectional spectroradiometers
Angelika Niedzwiedz, Jens Duffert, Mario Tobar-Foster, Jan Wilko Heinzel, Günther Seckmeyer
Abstract
Angelika Niedzwiedz, Jens Duffert, Mario Tobar-Foster, Jan Wilko Heinzel, Günther Seckmeyer
Abstract
Abstract A mobile calibration system for a multidirectional spectroradiometer (MUDIS) to transfer the absolute radiometric calibration from the laboratory to the location of the outdoor-measurement (field calibrator) has been developed. The main part of the calibration system comprises an aluminium sphere with a diameter of 40 cm, mounting adapters and a ventilation system. The MUDIS device is capable of measuring spectral radiance from 320 to 600 nm in 113 different directions simultaneously within 1 s. When repeating radiance measurements inside the mobile field sphere, the relative standard deviation (RSD) for wavelengths between 320 and 600 nm is less than 1.8% (320 nm) for all directions with minimum RSD of 0.6% at 382 nm. The reproducibility depends not only on the wavelength but also on the individual fibre position on the hemispherical input optics, with maximum of 4.5% RSD, but most directions show a lower deviation. On average, the RSD for the channels is less than 0.9%. The calibrator enables measurements of the spectral radiance with less uncertainty than with the previous indirect calibration method, which uses measurements of a scanning reference array spectroradiometer.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract A mobile calibration system for a multidirectional spectroradiometer (MUDIS) to transfer the absolute radiometric calibration from the laboratory to the location of the outdoor-measurement (field calibrator) has been developed. The main part of the calibration system comprises an aluminium sphere with a diameter of 40 cm, mounting adapters and a ventilation system. The MUDIS device is capable of measuring spectral radiance from 320 to 600 nm in 113 different directions simultaneously within 1 s. When repeating radiance measurements inside the mobile field sphere, the relative standard deviation (RSD) for wavelengths between 320 and 600 nm is less than 1.8% (320 nm) for all directions with minimum RSD of 0.6% at 382 nm. The reproducibility depends not only on the wavelength but also on the individual fibre position on the hemispherical input optics, with maximum of 4.5% RSD, but most directions show a lower deviation. On average, the RSD for the channels is less than 0.9%. The calibrator enables measurements of the spectral radiance with less uncertainty than with the previous indirect calibration method, which uses measurements of a scanning reference array spectroradiometer.
Key concepts: Spectroradiometer, Radiance, Integrating sphere, Calibration, Optics, Wavelength, Remote sensing, Reproducibility