DEVELOPMENT OF STABILITY INDICATING RP-HPLC METHOD FOR SIMULTANEOUS ESTIMATION OF IVABRADINE AND METOPROLOL IN PHARMACEUTICAL DOSAGE FORM AND IN BLOOD PLASMA
Author information unavailable
Abstract
Open-access reader
Author information unavailable
Abstract
Open-access reader
A simple reverse phase HPLC method was developed for the simultaneous estimation of Ivabradine and Metoprolo in bulk and tablet form.Chromatography was performed by isocratic reverse phase separation on a stainless steel column 4.6 x 150mm, symmetry column packed with octa decyl silane bonded to porous silica (C18) with particle size 5 micron with mobile phase containing Methanol and phosphate buffer in the ratio of 50:50.The flow rate was 0.8 ml/ min and effluent was monitored at 260 nm.The retention times were 2.24 min and 2.66 min Metoprolol and Ivabradine respectively.The standard curve was linear over a working range of 25-150 µg/ml for Metoprolol and 5-30 µg/ml for Ivabradine and gave an average correlation coefficient of 0.999, and 0.999 for Metoprolol and Ivabradine respectively.The limit of quantitation (LOQ) of this method was 0.56 µg/ml and 3.8 µg/ml for Metoprolol and Ivabradine respectively.The absolute recovery was 99.96% for Metoprolol and 99.86 for Ivabradin.Degradation products produced as a result of stress studies did not interfere with the detection of Metoprolol and Ivabradine, the assay can thus be considered stability-indicating.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A simple reverse phase HPLC method was developed for the simultaneous estimation of Ivabradine and Metoprolo in bulk and tablet form.Chromatography was performed by isocratic reverse phase separation on a stainless steel column 4.6 x 150mm, symmetry column packed with octa decyl silane bonded to porous silica (C18) with particle size 5 micron with mobile phase containing Methanol and phosphate buffer in the ratio of 50:50.The flow rate was 0.8 ml/ min and effluent was monitored at 260 nm.The retention times were 2.24 min and 2.66 min Metoprolol and Ivabradine respectively.The standard curve was linear over a working range of 25-150 µg/ml for Metoprolol and 5-30 µg/ml for Ivabradine and gave an average correlation coefficient of 0.999, and 0.999 for Metoprolol and Ivabradine respectively.The limit of quantitation (LOQ) of this method was 0.56 µg/ml and 3.8 µg/ml for Metoprolol and Ivabradine respectively.The absolute recovery was 99.96% for Metoprolol and 99.86 for Ivabradin.Degradation products produced as a result of stress studies did not interfere with the detection of Metoprolol and Ivabradine, the assay can thus be considered stability-indicating.
Key concepts: Ivabradine, Metoprolol, Chromatography, Chemistry, Dosage form, Pharmacology, Medicine, Internal medicine