2021•2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)Requires access

Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables

Mohammad AlShaikh Saleh, Shady S. Refaat, Marek Olesz, Haitham Abu‐Rub

Open publisher page 3 citations

Abstract

This work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC voltages. DC voltages is considered in this study because of the rising implementation of HVDC cables worldwide. Therefore, it is of paramount importance to study the PD behavior originating from defects under DC voltages. Hence, classifying and diagnosing the defects taking place becomes crucial. In this paper, a 3D finite element analysis (FEA)-based modeling is considered to study the electrical treeing behavior using an embedded needle electrode in the XLPE insulation. The experiment entails PD tests with different applied high DC voltages (2.5, 5, 10, 11, and 12 kV) to study the impact on the initiation of PDs and ultimately tree growth. PD measurements were also investigated under AC voltages (7.1, 9.9, 11.3, 12.7, 14.1, and 17 kV) to compare them with PD results obtained with the applied DC voltage. The time-resolved partial discharge (TRPD) patterns are acquired for classifying the severity of the defect present in the XLPE insulation.

About this research paper

What this paper is about

This work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC voltages. DC voltages is considered in this study because of the rising implementation of HVDC cables worldwide. Therefore, it is of paramount importance to study the PD behavior originating from defects under DC voltages. Hence, classifying and diagnosing the defects taking place becomes crucial. In this paper, a 3D finite element analysis (FEA)-based modeling is considered to study the electrical treeing behavior using an embedded needle electrode in the XLPE insulation. The experiment entails PD tests with different applied high DC voltages (2.5, 5, 10, 11, and 12 kV) to study the impact on the initiation of PDs and ultimately tree growth. PD measurements were also investigated under AC voltages (7.1, 9.9, 11.3, 12.7, 14.1, and 17 kV) to compare them with PD results obtained with the applied DC voltage. The time-resolved partial discharge (TRPD) patterns are acquired for classifying the severity of the defect present in the XLPE insulation.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This work investigates the impact of an applied AC and DC high voltage on the electrical tree behavior in extruded cross-linked polyethylene (XLPE) insulation based on simulation and experimental validation. Extensive partial discharge (PD) testing methods are being implemented for high voltage cables under AC voltage for monitoring their condition. However, these PD testing methods cannot be utilized for power cables under DC voltages. DC voltages is considered in this study because of the rising implementation of HVDC cables worldwide. Therefore, it is of paramount importance to study the PD behavior originating from defects under DC voltages. Hence, classifying and diagnosing the defects taking place becomes crucial. In this paper, a 3D finite element analysis (FEA)-based modeling is considered to study the electrical treeing behavior using an embedded needle electrode in the XLPE insulation. The experiment entails PD tests with different applied high DC voltages (2.5, 5, 10, 11, and 12 kV) to study the impact on the initiation of PDs and ultimately tree growth. PD measurements were also investigated under AC voltages (7.1, 9.9, 11.3, 12.7, 14.1, and 17 kV) to compare them with PD results obtained with the applied DC voltage. The time-resolved partial discharge (TRPD) patterns are acquired for classifying the severity of the defect present in the XLPE insulation.

Key concepts: Electrical treeing, Partial discharge, Voltage, Materials science, Cross-linked polyethylene, High voltage, Electrical engineering, Polyethylene

Related papers

Back to paper searchBrowse research topicsOriginal source
Electrical Tree Growth Behavior Under AC and DC High Voltage in Power Cables — Research Paper | ScholarLens