2022•Human ImmunologyOpen access

Concurrent use of two independent methods prevents erroneous HLA typing of deceased organ donors – An important strategy for patient safety and accurate virtual crossmatching for broader sharing

Thea dela Cruz, Charlyn Dames, Louise Pagaduan, Young Susan Cho, Denice Kong, Raja Rajalingam

Open full text 11 citations

Abstract

Comprehensive and accurate human leukocyte antigen (HLA) typing within a short turnaround time is a crucial initial step for allocating deceased donor organs for transplantation. Erroneous HLA typing of deceased donors can be catastrophic and result in recipient death, failed transplant, and organ wastage due to inappropriately matched donors. The real-time polymerase chain reaction method is widely used as the sole method for HLA typing of deceased donors because of its simplified workflow. Herein, we have reported cases of four deceased donors showing discrepant HLA typing discovered using two independent methods concurrently. The HLA typing of these donors could have been erroneously reported if a single method had been used, which would have profound patient safety implications. In one case, the drop out of HLA-DR7 using a single method could have resulted in harmful organ allocation if the organ was transplanted after a virtual crossmatch to a sensitized candidate showing strong donor-specific HLA-DR7 antibodies. In conclusion, this case series suggests that concurrent dual typing is essential for accurate HLA typing of deceased donors. This strategy is vital because precise HLA typing is critical for accurate virtual crossmatching, which facilitates continuous distribution and broader geographic sharing of the deceased donor organ.

Open-access reader

About this research paper

What this paper is about

Comprehensive and accurate human leukocyte antigen (HLA) typing within a short turnaround time is a crucial initial step for allocating deceased donor organs for transplantation. Erroneous HLA typing of deceased donors can be catastrophic and result in recipient death, failed transplant, and organ wastage due to inappropriately matched donors. The real-time polymerase chain reaction method is widely used as the sole method for HLA typing of deceased donors because of its simplified workflow. Herein, we have reported cases of four deceased donors showing discrepant HLA typing discovered using two independent methods concurrently. The HLA typing of these donors could have been erroneously reported if a single method had been used, which would have profound patient safety implications. In one case, the drop out of HLA-DR7 using a single method could have resulted in harmful organ allocation if the organ was transplanted after a virtual crossmatch to a sensitized candidate showing strong donor-specific HLA-DR7 antibodies. In conclusion, this case series suggests that concurrent dual typing is essential for accurate HLA typing of deceased donors. This strategy is vital because precise HLA typing is critical for accurate virtual crossmatching, which facilitates continuous distribution and broader geographic sharing of the deceased donor organ.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Comprehensive and accurate human leukocyte antigen (HLA) typing within a short turnaround time is a crucial initial step for allocating deceased donor organs for transplantation. Erroneous HLA typing of deceased donors can be catastrophic and result in recipient death, failed transplant, and organ wastage due to inappropriately matched donors. The real-time polymerase chain reaction method is widely used as the sole method for HLA typing of deceased donors because of its simplified workflow. Herein, we have reported cases of four deceased donors showing discrepant HLA typing discovered using two independent methods concurrently. The HLA typing of these donors could have been erroneously reported if a single method had been used, which would have profound patient safety implications. In one case, the drop out of HLA-DR7 using a single method could have resulted in harmful organ allocation if the organ was transplanted after a virtual crossmatch to a sensitized candidate showing strong donor-specific HLA-DR7 antibodies. In conclusion, this case series suggests that concurrent dual typing is essential for accurate HLA typing of deceased donors. This strategy is vital because precise HLA typing is critical for accurate virtual crossmatching, which facilitates continuous distribution and broader geographic sharing of the deceased donor organ.

Key concepts: Typing, Human leukocyte antigen, Tissue typing, Medicine, Organ transplantation, Immunology, Histocompatibility Testing, Transplantation

Related papers

Back to paper searchBrowse research topicsOriginal source
Concurrent use of two independent methods prevents erroneous HLA typing of deceased organ donors – An important strategy for patient safety and accurate virtual crossmatching for broader sharing — Research Paper | ScholarLens