2022Geophysical Journal InternationalOpen access

On the use of the microtremor HVSR for tracking velocity changes: a case study in Campo de Dalías basin (SE Spain)

Helena Seivane, Antonio García‐Jerez, Manuel Campiñez Navarro, L. T. Molina, Francisco Navarro-Martínez

Open full text 20 citations

Abstract

SUMMARY The stability of the low-frequency peaks (<1 Hz) obtained in the passive seismic survey of Campo de Dalías basin (CDB) by applying the horizontal-to-vertical spectral ratio (HVSR) method was investigated. Three temporary seismic stations were installed in remote sites that enabled studying the stationarity of their characteristic microtremor HVSR (MHVSR) shapes. All stations began to operate in mid-2016 and recorded at least 1 yr of continuous seismic ambient noise data, having up to 2 yr in some. Each seismic station was counted with a monitored borehole in their vicinity, registering the groundwater level every 30 min. The MHVSR curves were calculated for time windows of 150 s and averaged hourly. Four parameters have been defined to characterize the shape of the MHVSR around the main peak and to compare them with several environmental variables. Correlations between MHVSR characteristics and the groundwater level are shown to be the most persistent. The robustness of MHVSR method for applications to seismic engineering was not found to be compromised since the observed variations were within the margins of acceptable deviations. The results of this study have widen the possibilities of the MHVSR method from being a reliable predictor for seismic resonance to also being an autonomous monitoring tool, especially sensitive to the S-wave modifications.

Open-access reader

About this research paper

What this paper is about

SUMMARY The stability of the low-frequency peaks (<1 Hz) obtained in the passive seismic survey of Campo de Dalías basin (CDB) by applying the horizontal-to-vertical spectral ratio (HVSR) method was investigated. Three temporary seismic stations were installed in remote sites that enabled studying the stationarity of their characteristic microtremor HVSR (MHVSR) shapes. All stations began to operate in mid-2016 and recorded at least 1 yr of continuous seismic ambient noise data, having up to 2 yr in some. Each seismic station was counted with a monitored borehole in their vicinity, registering the groundwater level every 30 min. The MHVSR curves were calculated for time windows of 150 s and averaged hourly. Four parameters have been defined to characterize the shape of the MHVSR around the main peak and to compare them with several environmental variables. Correlations between MHVSR characteristics and the groundwater level are shown to be the most persistent. The robustness of MHVSR method for applications to seismic engineering was not found to be compromised since the observed variations were within the margins of acceptable deviations. The results of this study have widen the possibilities of the MHVSR method from being a reliable predictor for seismic resonance to also being an autonomous monitoring tool, especially sensitive to the S-wave modifications.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

SUMMARY The stability of the low-frequency peaks (<1 Hz) obtained in the passive seismic survey of Campo de Dalías basin (CDB) by applying the horizontal-to-vertical spectral ratio (HVSR) method was investigated. Three temporary seismic stations were installed in remote sites that enabled studying the stationarity of their characteristic microtremor HVSR (MHVSR) shapes. All stations began to operate in mid-2016 and recorded at least 1 yr of continuous seismic ambient noise data, having up to 2 yr in some. Each seismic station was counted with a monitored borehole in their vicinity, registering the groundwater level every 30 min. The MHVSR curves were calculated for time windows of 150 s and averaged hourly. Four parameters have been defined to characterize the shape of the MHVSR around the main peak and to compare them with several environmental variables. Correlations between MHVSR characteristics and the groundwater level are shown to be the most persistent. The robustness of MHVSR method for applications to seismic engineering was not found to be compromised since the observed variations were within the margins of acceptable deviations. The results of this study have widen the possibilities of the MHVSR method from being a reliable predictor for seismic resonance to also being an autonomous monitoring tool, especially sensitive to the S-wave modifications.

Key concepts: Microtremor, Geology, Seismology, Seismic noise, Passive seismic, Borehole, Structural basin, Ambient noise level

Related papers

Back to paper searchBrowse research topicsOriginal source
On the use of the microtremor HVSR for tracking velocity changes: a case study in Campo de Dalías basin (SE Spain) — Research Paper | ScholarLens