2022European Journal of PainOpen access

Placebo response varies between different types of sham acupuncture: A randomized double‐blind trial in neck pain patients

Dian Zeng, Xiaoxia Yan, Hongmei Deng, Jiemei Li, Jiaxin Xiao, Jiawei Yuan, Jianpeng Huang, Nenggui Xu, Wenbin Fu, Jianhua Liu

Open full text 55 citations

Abstract

BACKGROUND: In prospective experimental studies of neck pain patients, it is difficult to determine whether responses to sham acupuncture differ from responses to real acupuncture due to the heterogeneous methodologies in control/sham interventions. Here we aim to compare the specific and nonspecific effects of electroacupuncture with four types of sham acupuncture. METHODS: In this double-blind, sham-controlled study, we randomly assigned 175 patients with neck pain to receive 10 sessions of electroacupuncture, shallow puncture, nonacupoint deep puncture, nonacupoint shallow puncture, or nonpenetration acupuncture. We used the Northwick Park Neck Pain Questionnaire (NPQ) as our primary outcome, and Short-form McGill Pain Questionnaire, visual analog scale (VAS), and Pain Threshold as secondary outcomes to measure the changes from baseline to a 3-month follow up. RESULTS: All groups, except nonacupoint shallow puncture, had significant improvement in all outcome measurements. Electroacupuncture only showed superior improvements than the shallow puncture, nonacupoint shallow puncture, and nonpenetration groups when compared using the NPQ and VAS scale (*p < 0.001). Interestingly, the nonacupoint shallow puncture produced even less placebo response than nonpenetration acupuncture. CONCLUSION: Our study demonstrates the high variability of placebo response among different types of sham controls depending on the depth of needle insertion and the puncture location. An important implication of our results is nonacupoint deep puncture produced similar analgesic effects as electroacupuncture. Our study may shed a new light on the predominant underlying mechanisms among different types of sham acupuncture controls, which can help with interpreting the effect of acupuncture in other studies. TRIAL REGISTRATION: Chinese clinical trial registry (ChiCTR-IOR-15006886). SIGNIFICANCE: This study compared the observed specific and nonspecific analgesia effect in four different types of sham acupuncture stimulation with neck pain patients, assessed by four outcomes. Although all of the sham controls produced significant reduction in neck pain, electroacupuncture had superior significant improvement. Importantly, placebo responses differed significantly between the sham controls and responses were inconsistent according to different outcome assessments. This study emphasizes the importance of taking into consideration which sham control and method of outcome measurement were used in a pain research study when evaluating its results.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: In prospective experimental studies of neck pain patients, it is difficult to determine whether responses to sham acupuncture differ from responses to real acupuncture due to the heterogeneous methodologies in control/sham interventions. Here we aim to compare the specific and nonspecific effects of electroacupuncture with four types of sham acupuncture. METHODS: In this double-blind, sham-controlled study, we randomly assigned 175 patients with neck pain to receive 10 sessions of electroacupuncture, shallow puncture, nonacupoint deep puncture, nonacupoint shallow puncture, or nonpenetration acupuncture. We used the Northwick Park Neck Pain Questionnaire (NPQ) as our primary outcome, and Short-form McGill Pain Questionnaire, visual analog scale (VAS), and Pain Threshold as secondary outcomes to measure the changes from baseline to a 3-month follow up. RESULTS: All groups, except nonacupoint shallow puncture, had significant improvement in all outcome measurements. Electroacupuncture only showed superior improvements than the shallow puncture, nonacupoint shallow puncture, and nonpenetration groups when compared using the NPQ and VAS scale (*p < 0.001). Interestingly, the nonacupoint shallow puncture produced even less placebo response than nonpenetration acupuncture. CONCLUSION: Our study demonstrates the high variability of placebo response among different types of sham controls depending on the depth of needle insertion and the puncture location. An important implication of our results is nonacupoint deep puncture produced similar analgesic effects as electroacupuncture. Our study may shed a new light on the predominant underlying mechanisms among different types of sham acupuncture controls, which can help with interpreting the effect of acupuncture in other studies. TRIAL REGISTRATION: Chinese clinical trial registry (ChiCTR-IOR-15006886). SIGNIFICANCE: This study compared the observed specific and nonspecific analgesia effect in four different types of sham acupuncture stimulation with neck pain patients, assessed by four outcomes. Although all of the sham controls produced significant reduction in neck pain, electroacupuncture had superior significant improvement. Importantly, placebo responses differed significantly between the sham controls and responses were inconsistent according to different outcome assessments. This study emphasizes the importance of taking into consideration which sham control and method of outcome measurement were used in a pain research study when evaluating its results.

Why it matters

OpenAlex reports 55 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: In prospective experimental studies of neck pain patients, it is difficult to determine whether responses to sham acupuncture differ from responses to real acupuncture due to the heterogeneous methodologies in control/sham interventions. Here we aim to compare the specific and nonspecific effects of electroacupuncture with four types of sham acupuncture. METHODS: In this double-blind, sham-controlled study, we randomly assigned 175 patients with neck pain to receive 10 sessions of electroacupuncture, shallow puncture, nonacupoint deep puncture, nonacupoint shallow puncture, or nonpenetration acupuncture. We used the Northwick Park Neck Pain Questionnaire (NPQ) as our primary outcome, and Short-form McGill Pain Questionnaire, visual analog scale (VAS), and Pain Threshold as secondary outcomes to measure the changes from baseline to a 3-month follow up. RESULTS: All groups, except nonacupoint shallow puncture, had significant improvement in all outcome measurements. Electroacupuncture only showed superior improvements than the shallow puncture, nonacupoint shallow puncture, and nonpenetration groups when compared using the NPQ and VAS scale (*p < 0.001). Interestingly, the nonacupoint shallow puncture produced even less placebo response than nonpenetration acupuncture. CONCLUSION: Our study demonstrates the high variability of placebo response among different types of sham controls depending on the depth of needle insertion and the puncture location. An important implication of our results is nonacupoint deep puncture produced similar analgesic effects as electroacupuncture. Our study may shed a new light on the predominant underlying mechanisms among different types of sham acupuncture controls, which can help with interpreting the effect of acupuncture in other studies. TRIAL REGISTRATION: Chinese clinical trial registry (ChiCTR-IOR-15006886). SIGNIFICANCE: This study compared the observed specific and nonspecific analgesia effect in four different types of sham acupuncture stimulation with neck pain patients, assessed by four outcomes. Although all of the sham controls produced significant reduction in neck pain, electroacupuncture had superior significant improvement. Importantly, placebo responses differed significantly between the sham controls and responses were inconsistent according to different outcome assessments. This study emphasizes the importance of taking into consideration which sham control and method of outcome measurement were used in a pain research study when evaluating its results.

Key concepts: Placebo, Acupuncture, Medicine, Neck pain, Double blind, Placebo response, Physical therapy, Randomized controlled trial

Related papers

Back to paper searchBrowse research topicsOriginal source
Placebo response varies between different types of sham acupuncture: A randomized double‐blind trial in neck pain patients — Research Paper | ScholarLens