2022Journal of Radiological ProtectionRequires access

Uncertainties in occupational eye lens doses from dosimeters over the apron in interventional practices

Roberto Sánchez, E. Vañó, J. Fernández

Open publisher page 2 citations

Abstract

Abstract It is relevant to estimate the uncertainties in the measurement of eye lens doses from a personal dosimeter over the protective apron without using additional dosimetry near the eyes. Additional dosimetry for interventionists represents a difficulty for routine clinical practice. This study analyses the estimated eye doses from dosimeter values taken at chest level over the apron and their uncertainties. Measurements of H p(0.07) using optically stimulated luminescence dosimeters located on the chest over the apron and on the glasses (in the inner and outer part of the protection) were taken from ten interventionalists in a university hospital, in the period 2018–2019 during standard clinical practice. For a total sample of 133 interventional procedures included in our study, the ratio between the H p(0.07) on the glasses (left-outer side) and on the chest over the apron had an average of 0.74, with quartiles of 0.47, 0.64, 0.88. Statistically significant differences were found among operators using the U-Mann–Whitney test. The average transmission factor for the glasses was 0.30, with quartiles of 0.21, 0.25, and 0.32. Different complexity in the procedures, in the quality of the scatter radiation and in the individual operational practices, involve a relevant dispersion in the results for lens dose estimations from the over apron dosimeter. Lens doses may be between a 64% and an 88% of the over apron dosimeter values (using median or 3rd quartile). The use of 88% may be a conservative approach.

About this research paper

What this paper is about

Abstract It is relevant to estimate the uncertainties in the measurement of eye lens doses from a personal dosimeter over the protective apron without using additional dosimetry near the eyes. Additional dosimetry for interventionists represents a difficulty for routine clinical practice. This study analyses the estimated eye doses from dosimeter values taken at chest level over the apron and their uncertainties. Measurements of H p(0.07) using optically stimulated luminescence dosimeters located on the chest over the apron and on the glasses (in the inner and outer part of the protection) were taken from ten interventionalists in a university hospital, in the period 2018–2019 during standard clinical practice. For a total sample of 133 interventional procedures included in our study, the ratio between the H p(0.07) on the glasses (left-outer side) and on the chest over the apron had an average of 0.74, with quartiles of 0.47, 0.64, 0.88. Statistically significant differences were found among operators using the U-Mann–Whitney test. The average transmission factor for the glasses was 0.30, with quartiles of 0.21, 0.25, and 0.32. Different complexity in the procedures, in the quality of the scatter radiation and in the individual operational practices, involve a relevant dispersion in the results for lens dose estimations from the over apron dosimeter. Lens doses may be between a 64% and an 88% of the over apron dosimeter values (using median or 3rd quartile). The use of 88% may be a conservative approach.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract It is relevant to estimate the uncertainties in the measurement of eye lens doses from a personal dosimeter over the protective apron without using additional dosimetry near the eyes. Additional dosimetry for interventionists represents a difficulty for routine clinical practice. This study analyses the estimated eye doses from dosimeter values taken at chest level over the apron and their uncertainties. Measurements of H p(0.07) using optically stimulated luminescence dosimeters located on the chest over the apron and on the glasses (in the inner and outer part of the protection) were taken from ten interventionalists in a university hospital, in the period 2018–2019 during standard clinical practice. For a total sample of 133 interventional procedures included in our study, the ratio between the H p(0.07) on the glasses (left-outer side) and on the chest over the apron had an average of 0.74, with quartiles of 0.47, 0.64, 0.88. Statistically significant differences were found among operators using the U-Mann–Whitney test. The average transmission factor for the glasses was 0.30, with quartiles of 0.21, 0.25, and 0.32. Different complexity in the procedures, in the quality of the scatter radiation and in the individual operational practices, involve a relevant dispersion in the results for lens dose estimations from the over apron dosimeter. Lens doses may be between a 64% and an 88% of the over apron dosimeter values (using median or 3rd quartile). The use of 88% may be a conservative approach.

Key concepts: Dosimeter, Lead apron, Dosimetry, Eye lens, Quartile, Equivalent dose, Medicine, Radiation protection

Related papers

Back to paper searchBrowse research topicsOriginal source
Uncertainties in occupational eye lens doses from dosimeters over the apron in interventional practices — Research Paper | ScholarLens