2022IEEE Transactions on Plasma ScienceRequires access

The Twin-Probe Method: Improving Langmuir Probe Measurements on Small Spacecraft

Omar Leon, Jesse McTernan, Jason Vaughn, Todd Schneider, Grant Miars, Walter R. Hoegy, Brian Gilchrist

Open publisher page 14 citations

Abstract

The Langmuir probe (LP) is generally accepted as an effective and relatively simplein situspace plasma instrument (plasma density, electron temperature, and spacecraft potential). As LPs transition to small spacecraft, their implementation encounters new technical challenges. For example, a negative charge is induced on the spacecraft while positively biasing an LP due to the small surface area ratios (spacecraft surface area to probe surface area ≪ 1000). This results in a varying spacecraft potential that degrades the accuracy of electron temperature and electron density measurements, reducing the LP’s effectiveness as a diagnostic tool. To mitigate the effects of this spacecraft charging, the twin-probe method (TPM) was developed. The TPM corrects LP measurements with tracked spacecraft potentials, measured by a separate high-impedance probe. By accounting for the changes in the spacecraft potential, the LP sweeps can be reconstructed to provide more accurate measurements of the ambient plasma’s properties. Here, we detail the TPM and present laboratory experiments that study its effectiveness and summarize constraints. Through these experiments, we found that it is possible to correct for spacecraft charging effects that can cause deviations in temperature and density as large as 20% and 136%, respectively. Furthermore, we will demonstrate a clear correlation between area ratio, spacecraft charging, and the negative impact on temperature and density measurement accuracy.

About this research paper

What this paper is about

The Langmuir probe (LP) is generally accepted as an effective and relatively simplein situspace plasma instrument (plasma density, electron temperature, and spacecraft potential). As LPs transition to small spacecraft, their implementation encounters new technical challenges. For example, a negative charge is induced on the spacecraft while positively biasing an LP due to the small surface area ratios (spacecraft surface area to probe surface area ≪ 1000). This results in a varying spacecraft potential that degrades the accuracy of electron temperature and electron density measurements, reducing the LP’s effectiveness as a diagnostic tool. To mitigate the effects of this spacecraft charging, the twin-probe method (TPM) was developed. The TPM corrects LP measurements with tracked spacecraft potentials, measured by a separate high-impedance probe. By accounting for the changes in the spacecraft potential, the LP sweeps can be reconstructed to provide more accurate measurements of the ambient plasma’s properties. Here, we detail the TPM and present laboratory experiments that study its effectiveness and summarize constraints. Through these experiments, we found that it is possible to correct for spacecraft charging effects that can cause deviations in temperature and density as large as 20% and 136%, respectively. Furthermore, we will demonstrate a clear correlation between area ratio, spacecraft charging, and the negative impact on temperature and density measurement accuracy.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The Langmuir probe (LP) is generally accepted as an effective and relatively simplein situspace plasma instrument (plasma density, electron temperature, and spacecraft potential). As LPs transition to small spacecraft, their implementation encounters new technical challenges. For example, a negative charge is induced on the spacecraft while positively biasing an LP due to the small surface area ratios (spacecraft surface area to probe surface area ≪ 1000). This results in a varying spacecraft potential that degrades the accuracy of electron temperature and electron density measurements, reducing the LP’s effectiveness as a diagnostic tool. To mitigate the effects of this spacecraft charging, the twin-probe method (TPM) was developed. The TPM corrects LP measurements with tracked spacecraft potentials, measured by a separate high-impedance probe. By accounting for the changes in the spacecraft potential, the LP sweeps can be reconstructed to provide more accurate measurements of the ambient plasma’s properties. Here, we detail the TPM and present laboratory experiments that study its effectiveness and summarize constraints. Through these experiments, we found that it is possible to correct for spacecraft charging effects that can cause deviations in temperature and density as large as 20% and 136%, respectively. Furthermore, we will demonstrate a clear correlation between area ratio, spacecraft charging, and the negative impact on temperature and density measurement accuracy.

Key concepts: Spacecraft, Spacecraft charging, Langmuir probe, Plasma, Electron density, Electron temperature, Physics, Aerospace engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
The Twin-Probe Method: Improving Langmuir Probe Measurements on Small Spacecraft — Research Paper | ScholarLens