2006Unpublished venueOpen access

The water vapour distribution in the Arctic lowermost stratosphere during LAUTLOS campaign and related transport processes including stratosphere-troposphere exchange

Alexey Yu. Karpechko, A. Lukyanov, E. Kyrö, S. Khaikin, L. I. Korshunov, Rigel Kivi, Holger Vömel

Open full text 0 citations

Abstract

Abstract. Balloon-borne water vapour measurements during January and February 2004, which were obtained as part of the LAUTLOS campaign at Sodankylä, Finland, 67° N, were used to analyse the water vapour distribution in the wintertime Arctic lowermost stratosphere. A 2.5 km thick layer (or 30 K in the potential temperature scale) above the local tropopause is characterized by a significant water vapour variability on a synoptic timescale with values between stratospheric and tropospheric, which is in good agreement with previously reported measurements. A cross-correlation analysis of ozone and water vapour confirms that this layer contains a mixture of stratospheric and tropospheric air masses. Some of the flights sampled laminae of enhanced water vapour above the tropopause. Meteorological analyses and backward trajectory calculations show that these features are related to filaments that had developed along the flanks of cut-off anticyclones, which had been active at this time over the Northern Atlantic. Cross-tropopause mass fluxes calculated following the Wei method are used to identify regions and processes that are important for stratosphere-troposphere exchange (STE) in high-latitudes. Intensive STE occurs around cut-off anticyclones in regions of strong winds, where calculations suggest the presence of developed clear-air turbulence. The decay of the filaments is also shown to be important for STE.

Open-access reader

About this research paper

What this paper is about

Abstract. Balloon-borne water vapour measurements during January and February 2004, which were obtained as part of the LAUTLOS campaign at Sodankylä, Finland, 67° N, were used to analyse the water vapour distribution in the wintertime Arctic lowermost stratosphere. A 2.5 km thick layer (or 30 K in the potential temperature scale) above the local tropopause is characterized by a significant water vapour variability on a synoptic timescale with values between stratospheric and tropospheric, which is in good agreement with previously reported measurements. A cross-correlation analysis of ozone and water vapour confirms that this layer contains a mixture of stratospheric and tropospheric air masses. Some of the flights sampled laminae of enhanced water vapour above the tropopause. Meteorological analyses and backward trajectory calculations show that these features are related to filaments that had developed along the flanks of cut-off anticyclones, which had been active at this time over the Northern Atlantic. Cross-tropopause mass fluxes calculated following the Wei method are used to identify regions and processes that are important for stratosphere-troposphere exchange (STE) in high-latitudes. Intensive STE occurs around cut-off anticyclones in regions of strong winds, where calculations suggest the presence of developed clear-air turbulence. The decay of the filaments is also shown to be important for STE.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract. Balloon-borne water vapour measurements during January and February 2004, which were obtained as part of the LAUTLOS campaign at Sodankylä, Finland, 67° N, were used to analyse the water vapour distribution in the wintertime Arctic lowermost stratosphere. A 2.5 km thick layer (or 30 K in the potential temperature scale) above the local tropopause is characterized by a significant water vapour variability on a synoptic timescale with values between stratospheric and tropospheric, which is in good agreement with previously reported measurements. A cross-correlation analysis of ozone and water vapour confirms that this layer contains a mixture of stratospheric and tropospheric air masses. Some of the flights sampled laminae of enhanced water vapour above the tropopause. Meteorological analyses and backward trajectory calculations show that these features are related to filaments that had developed along the flanks of cut-off anticyclones, which had been active at this time over the Northern Atlantic. Cross-tropopause mass fluxes calculated following the Wei method are used to identify regions and processes that are important for stratosphere-troposphere exchange (STE) in high-latitudes. Intensive STE occurs around cut-off anticyclones in regions of strong winds, where calculations suggest the presence of developed clear-air turbulence. The decay of the filaments is also shown to be important for STE.

Key concepts: Stratosphere, Troposphere, Tropopause, Anticyclone, Water vapor, Atmospheric sciences, Environmental science, Climatology

Related papers

Back to paper searchBrowse research topicsOriginal source
The water vapour distribution in the Arctic lowermost stratosphere during LAUTLOS campaign and related transport processes including stratosphere-troposphere exchange — Research Paper | ScholarLens