Comparison between Energy Simulation and Monitoring Data in an Office Building
Koldobika Martín-Escudero, Garazi Atxalandabaso, Aitor Erkoreka, Amaia Uriarte, Matteo Porta
Abstract
Open-access reader
Koldobika Martín-Escudero, Garazi Atxalandabaso, Aitor Erkoreka, Amaia Uriarte, Matteo Porta
Abstract
Open-access reader
One of the most important steps in the retrofitting process of a building is to understand its pre-retrofitting stage energy performance. The best choice for carrying this out is by means of a calibrated building energy simulation (BES) model. Then, the testing of different retrofitting solutions in the validated model allows for quantifying the improvements that may be obtained, in order to choose the most suitable solution. In this work, based on the available detailed building drawings, constructive details, building operational data and the data sets obtained on a minute basis (for a whole year) from a dedicated energy monitoring system, the calibration of an in-use office building energy model has been carried out. It has been possible to construct a detailed white box model based on Design Builder software. Then, comparing the model output for indoor air temperature, lighting consumption and heating consumption against the monitored data, some of the building envelope parameters and inner building inertia of the model were fine tuned to obtain fits fulfilling the ASHRAE criteria. Problems found during this fitting process and how they are solved are explained in detail. The model calibration is firstly performed on an hourly basis for a typical winter and summer week; then, the whole year results of the simulation are compared against the monitored data. The results show a good agreement for indoor temperature, lighting and heating consumption compared with the ASHRAE criteria for the mean bias error (MBE).
OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
One of the most important steps in the retrofitting process of a building is to understand its pre-retrofitting stage energy performance. The best choice for carrying this out is by means of a calibrated building energy simulation (BES) model. Then, the testing of different retrofitting solutions in the validated model allows for quantifying the improvements that may be obtained, in order to choose the most suitable solution. In this work, based on the available detailed building drawings, constructive details, building operational data and the data sets obtained on a minute basis (for a whole year) from a dedicated energy monitoring system, the calibration of an in-use office building energy model has been carried out. It has been possible to construct a detailed white box model based on Design Builder software. Then, comparing the model output for indoor air temperature, lighting consumption and heating consumption against the monitored data, some of the building envelope parameters and inner building inertia of the model were fine tuned to obtain fits fulfilling the ASHRAE criteria. Problems found during this fitting process and how they are solved are explained in detail. The model calibration is firstly performed on an hourly basis for a typical winter and summer week; then, the whole year results of the simulation are compared against the monitored data. The results show a good agreement for indoor temperature, lighting and heating consumption compared with the ASHRAE criteria for the mean bias error (MBE).
Key concepts: ASHRAE 90.1, Building energy simulation, Retrofitting, Building envelope, Energy consumption, Building model, Calibration, Process (computing)