2022•Journal of Cardiovascular ElectrophysiologyRequires access

Pulsed‐field ablation combined with ultrahigh‐density mapping in patients undergoing catheter ablation for atrial fibrillation: Practical and electrophysiological considerations

Melanie Gunawardene, Benjamin N. Schaeffer, Mario Jularic, Christian Eickholt, Tilman Maurer, Ruken Özge Akbulak, Max Flindt, Omar Anwar, Ulrich Frank Pape, Sebastian Maasberg, Nele Geßler, Jens Hartmann, Stephan Willems

Open publisher page 72 citations

Abstract

BACKGROUND: Pulsed-field ablation (PFA) yields a novel ablation technology for atrial fibrillation (AF). PFA lesions promise to be highly durable, however clinical data on lesion characteristics are still limited. OBJECTIVE: This study sought to investigate PFA lesion creation with ultrahigh-density (UHDx) mapping. METHODS: Consecutive AF patients underwent PFA-based pulmonary vein isolation (PVI) using a multispline catheter (Farwave, Farapulse Inc.). Additional ablation, including left atrial posterior wall isolation (LAPWI) and mitral isthmus ablation (MI) were performed in a subset of persistent AF patients. The extent of PFA-lesions and decrease of LA-voltage were assessed with pre- and post PFA UHDx-mapping (Orion™ catheter and Rhythmia™ 3D-mapping system, Boston Scientific). RESULTS: In 20 patients, acute PVI was achieved in 80/80 PVs, LAPW isolation in 9/9 patients, MI ablation in 2/2 (procedure time: 123 ± 21.6 min, fluoroscopy time: 19.2 ± 5.5 min). UHDx-mapping subsequent to PVI revealed early PV-reconnection in five case (5/80, 6.25%). Gaps were located at the anterior-superior PV ostia and were successfully targeted with additional PFA. Repeat UHDx mapping after PFA revealed a significant decrease of voltage along the PV ostia (1.67 ± 1.36 mV vs. 0.053 ± 0.038 mV, p < .0001) with almost no complex electrogram-fractionation at the lesion border zones. PFA-catheter visualization within the mapping system was feasible in 17/19 (84.9%) patients and adequate in 92.9% of ablation sites. CONCLUSION: For the first time illustrated by UHDx mapping, PFA creates wide antral circumferential lesions and homogenous LAPW isolation with depression of tissue voltage to a minimum. Although with a low incidence, early PV reconnection can still occur also in the setting of PFA.

About this research paper

What this paper is about

BACKGROUND: Pulsed-field ablation (PFA) yields a novel ablation technology for atrial fibrillation (AF). PFA lesions promise to be highly durable, however clinical data on lesion characteristics are still limited. OBJECTIVE: This study sought to investigate PFA lesion creation with ultrahigh-density (UHDx) mapping. METHODS: Consecutive AF patients underwent PFA-based pulmonary vein isolation (PVI) using a multispline catheter (Farwave, Farapulse Inc.). Additional ablation, including left atrial posterior wall isolation (LAPWI) and mitral isthmus ablation (MI) were performed in a subset of persistent AF patients. The extent of PFA-lesions and decrease of LA-voltage were assessed with pre- and post PFA UHDx-mapping (Orion™ catheter and Rhythmia™ 3D-mapping system, Boston Scientific). RESULTS: In 20 patients, acute PVI was achieved in 80/80 PVs, LAPW isolation in 9/9 patients, MI ablation in 2/2 (procedure time: 123 ± 21.6 min, fluoroscopy time: 19.2 ± 5.5 min). UHDx-mapping subsequent to PVI revealed early PV-reconnection in five case (5/80, 6.25%). Gaps were located at the anterior-superior PV ostia and were successfully targeted with additional PFA. Repeat UHDx mapping after PFA revealed a significant decrease of voltage along the PV ostia (1.67 ± 1.36 mV vs. 0.053 ± 0.038 mV, p < .0001) with almost no complex electrogram-fractionation at the lesion border zones. PFA-catheter visualization within the mapping system was feasible in 17/19 (84.9%) patients and adequate in 92.9% of ablation sites. CONCLUSION: For the first time illustrated by UHDx mapping, PFA creates wide antral circumferential lesions and homogenous LAPW isolation with depression of tissue voltage to a minimum. Although with a low incidence, early PV reconnection can still occur also in the setting of PFA.

Why it matters

OpenAlex reports 72 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Pulsed-field ablation (PFA) yields a novel ablation technology for atrial fibrillation (AF). PFA lesions promise to be highly durable, however clinical data on lesion characteristics are still limited. OBJECTIVE: This study sought to investigate PFA lesion creation with ultrahigh-density (UHDx) mapping. METHODS: Consecutive AF patients underwent PFA-based pulmonary vein isolation (PVI) using a multispline catheter (Farwave, Farapulse Inc.). Additional ablation, including left atrial posterior wall isolation (LAPWI) and mitral isthmus ablation (MI) were performed in a subset of persistent AF patients. The extent of PFA-lesions and decrease of LA-voltage were assessed with pre- and post PFA UHDx-mapping (Orion™ catheter and Rhythmia™ 3D-mapping system, Boston Scientific). RESULTS: In 20 patients, acute PVI was achieved in 80/80 PVs, LAPW isolation in 9/9 patients, MI ablation in 2/2 (procedure time: 123 ± 21.6 min, fluoroscopy time: 19.2 ± 5.5 min). UHDx-mapping subsequent to PVI revealed early PV-reconnection in five case (5/80, 6.25%). Gaps were located at the anterior-superior PV ostia and were successfully targeted with additional PFA. Repeat UHDx mapping after PFA revealed a significant decrease of voltage along the PV ostia (1.67 ± 1.36 mV vs. 0.053 ± 0.038 mV, p < .0001) with almost no complex electrogram-fractionation at the lesion border zones. PFA-catheter visualization within the mapping system was feasible in 17/19 (84.9%) patients and adequate in 92.9% of ablation sites. CONCLUSION: For the first time illustrated by UHDx mapping, PFA creates wide antral circumferential lesions and homogenous LAPW isolation with depression of tissue voltage to a minimum. Although with a low incidence, early PV reconnection can still occur also in the setting of PFA.

Key concepts: Pulmonary vein, Medicine, Ablation, Atrial fibrillation, Catheter ablation, Fluoroscopy, Lesion, Catheter

Related papers

Back to paper searchBrowse research topicsOriginal source
Pulsed‐field ablation combined with ultrahigh‐density mapping in patients undergoing catheter ablation for atrial fibrillation: Practical and electrophysiological considerations — Research Paper | ScholarLens