2021•AIP conference proceedingsRequires access

Performance of single-large simulated sunlight for indoor photovoltaic testing

Bayu Prasetiyo Utomo, Himma Firdaus, Qudsiyyatul Lailiyah, Winda Sari Ramadhani, Intan Paramudita

Open publisher page 0 citations

Abstract

Recently, there is enormous attention in developing indoor testing-based photovoltaic (PV) modules using simulated sunlight. In this study, the performance of simulated sunlight using a large tungsten halogen lamp was evaluated. The electrical characteristics and non-uniformity performance in the various lamp tilt angles and distances to the irradiated PV were determined and considered according to the standard of solar simulator performance requirements BS EN 60904-9. Results indicated that the present simulated sunlight reached a stable operation after around 10 minutes according to the current response. Meanwhile, the obtained wavelength range of present simulated sunlight indicated quite similar to the visible light. In term of spatial non-uniformity, the present simulated sunlight failed to meet the classification of a typical solar simulator according to BS EN 60904-9 with the non-uniformity level resulted in a higher percentage as the distance of the lamp to the irradiated PV decreased. The dispersion of unevenness value indicated that the configuration of simulated sunlight at 20° could be a reasonable option for performing the test at 0.3 m distance and 90° for distance over 0.3 m.

About this research paper

What this paper is about

Recently, there is enormous attention in developing indoor testing-based photovoltaic (PV) modules using simulated sunlight. In this study, the performance of simulated sunlight using a large tungsten halogen lamp was evaluated. The electrical characteristics and non-uniformity performance in the various lamp tilt angles and distances to the irradiated PV were determined and considered according to the standard of solar simulator performance requirements BS EN 60904-9. Results indicated that the present simulated sunlight reached a stable operation after around 10 minutes according to the current response. Meanwhile, the obtained wavelength range of present simulated sunlight indicated quite similar to the visible light. In term of spatial non-uniformity, the present simulated sunlight failed to meet the classification of a typical solar simulator according to BS EN 60904-9 with the non-uniformity level resulted in a higher percentage as the distance of the lamp to the irradiated PV decreased. The dispersion of unevenness value indicated that the configuration of simulated sunlight at 20° could be a reasonable option for performing the test at 0.3 m distance and 90° for distance over 0.3 m.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Recently, there is enormous attention in developing indoor testing-based photovoltaic (PV) modules using simulated sunlight. In this study, the performance of simulated sunlight using a large tungsten halogen lamp was evaluated. The electrical characteristics and non-uniformity performance in the various lamp tilt angles and distances to the irradiated PV were determined and considered according to the standard of solar simulator performance requirements BS EN 60904-9. Results indicated that the present simulated sunlight reached a stable operation after around 10 minutes according to the current response. Meanwhile, the obtained wavelength range of present simulated sunlight indicated quite similar to the visible light. In term of spatial non-uniformity, the present simulated sunlight failed to meet the classification of a typical solar simulator according to BS EN 60904-9 with the non-uniformity level resulted in a higher percentage as the distance of the lamp to the irradiated PV decreased. The dispersion of unevenness value indicated that the configuration of simulated sunlight at 20° could be a reasonable option for performing the test at 0.3 m distance and 90° for distance over 0.3 m.

Key concepts: Sunlight, Solar simulator, Halogen lamp, Photovoltaic system, Tilt (camera), Environmental science, Dispersion (optics), Optics

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of single-large simulated sunlight for indoor photovoltaic testing — Research Paper | ScholarLens