2021Applied SciencesOpen access

Interwoven versus Knitted Self-Expandable Metallic Stents: A Comparison Study of Stent-Induced Tissue Hyperplasia in the Rat Esophagus

Jeon Min Kang, Dongwook Oh, Song Hee Kim, Dae Sung Ryu, Yubeen Park, Dong‐Sung Won, Ji Won Kim, Chu Hui Zeng, Jung‐Hoon Park, Sang Soo Lee

Open full text 5 citations

Abstract

This study investigated whether interwoven self-expandable metallic stent (I-SEMS) placement suppresses stent-induced tissue hyperplasia compared with conventional knitted self-expandable metallic stent (K-SEMS) placement in a rat esophageal model. Twelve rats were randomly assigned to the I-SEMS (n = 6) and K-SEMS (n = 6) groups. All rats were sacrificed 4 weeks after the stent placement. The degree of stent-induced tissue hyperplasia on esophagography and histologic examination was compared between the groups. Stent placement was technically successful in all rats. Esophagography revealed significantly greater mean luminal diameter of the stented esophagus in the I-SEMS group than in the K-SEMS group (p < 0.001). Histologic examination revealed a significantly lower percentage of tissue hyperplasia area and a significantly thinner submucosal fibrosis in the I-SEMS group than in the K-SEMS group (all p < 0.001). There were no significant differences in the thickness of the epithelial layers (p = 0.290) and degree of inflammatory cell infiltration (p = 0.506). Formation of stent-induced tissue hyperplasia was evident with both I-SEMS and K-SEMS. Placement of I-SEMSs with a small cell size and high flexibility seems to be effective in suppressing stent-induced tissue hyperplasia compared with placement of K-SEMSs in rat esophageal models.

Open-access reader

About this research paper

What this paper is about

This study investigated whether interwoven self-expandable metallic stent (I-SEMS) placement suppresses stent-induced tissue hyperplasia compared with conventional knitted self-expandable metallic stent (K-SEMS) placement in a rat esophageal model. Twelve rats were randomly assigned to the I-SEMS (n = 6) and K-SEMS (n = 6) groups. All rats were sacrificed 4 weeks after the stent placement. The degree of stent-induced tissue hyperplasia on esophagography and histologic examination was compared between the groups. Stent placement was technically successful in all rats. Esophagography revealed significantly greater mean luminal diameter of the stented esophagus in the I-SEMS group than in the K-SEMS group (p < 0.001). Histologic examination revealed a significantly lower percentage of tissue hyperplasia area and a significantly thinner submucosal fibrosis in the I-SEMS group than in the K-SEMS group (all p < 0.001). There were no significant differences in the thickness of the epithelial layers (p = 0.290) and degree of inflammatory cell infiltration (p = 0.506). Formation of stent-induced tissue hyperplasia was evident with both I-SEMS and K-SEMS. Placement of I-SEMSs with a small cell size and high flexibility seems to be effective in suppressing stent-induced tissue hyperplasia compared with placement of K-SEMSs in rat esophageal models.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study investigated whether interwoven self-expandable metallic stent (I-SEMS) placement suppresses stent-induced tissue hyperplasia compared with conventional knitted self-expandable metallic stent (K-SEMS) placement in a rat esophageal model. Twelve rats were randomly assigned to the I-SEMS (n = 6) and K-SEMS (n = 6) groups. All rats were sacrificed 4 weeks after the stent placement. The degree of stent-induced tissue hyperplasia on esophagography and histologic examination was compared between the groups. Stent placement was technically successful in all rats. Esophagography revealed significantly greater mean luminal diameter of the stented esophagus in the I-SEMS group than in the K-SEMS group (p < 0.001). Histologic examination revealed a significantly lower percentage of tissue hyperplasia area and a significantly thinner submucosal fibrosis in the I-SEMS group than in the K-SEMS group (all p < 0.001). There were no significant differences in the thickness of the epithelial layers (p = 0.290) and degree of inflammatory cell infiltration (p = 0.506). Formation of stent-induced tissue hyperplasia was evident with both I-SEMS and K-SEMS. Placement of I-SEMSs with a small cell size and high flexibility seems to be effective in suppressing stent-induced tissue hyperplasia compared with placement of K-SEMSs in rat esophageal models.

Key concepts: Stent, Hyperplasia, Self-expandable metallic stent, Medicine, Esophagus, Urology, Pathology, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Interwoven versus Knitted Self-Expandable Metallic Stents: A Comparison Study of Stent-Induced Tissue Hyperplasia in the Rat Esophagus — Research Paper | ScholarLens