2021Journal of Occupational HealthOpen access

A multicenter study of radiation doses to the eye lenses of clinical physicians performing radiology procedures in Japan

Keisuke Nagamoto, Takashi Moritake, Koichi Nakagami, Koichi Morota, Satoru Matsuzaki, Naoki Kunugita

Open full text 19 citations

Abstract

PURPOSE: We investigated occupational dose to the lens of the eye for physicians engaged in radiology procedures. We evaluated the potential for compliance with the new-equivalent dose limits to the lens of the eye. Further, a "multiple radiation protection" protocol was proposed according to the basic principles of occupational health, and its effectiveness was estimated. METHODS: (3)) for each participant was measured using a small radio-photoluminescence glass dosimeter mounted on lead glasses. Physicians were directed to procedure multiple radiation protection measures to evaluate their usefulness. RESULTS: (3) reduced from 207.7 to 43.2 μSv/procedure and from 21.6 to 10.2 μSv/procedure in cardiovascular internal physician and cerebrovascular physician, respectively, after the implementation of the proposed multiple radiation protection measures. The dose reduction rate of these measures was 53% (range: 37%-79%). CONCLUSIONS: The radiation doses received by the eye lenses of physicians engaged in radiology procedure may exceed the dose limits to the lens of the eye if radio-protective equipment and imaging conditions are not properly controlled. However, based on the lens equivalent dose data, the implementation of "multiple radiation protection" according to the basic principles of occupational health can ensure compliance with the new-equivalent dose limits to the lens of the eye without placing an undue burden on individual physicians or medical facilities.

Open-access reader

About this research paper

What this paper is about

PURPOSE: We investigated occupational dose to the lens of the eye for physicians engaged in radiology procedures. We evaluated the potential for compliance with the new-equivalent dose limits to the lens of the eye. Further, a "multiple radiation protection" protocol was proposed according to the basic principles of occupational health, and its effectiveness was estimated. METHODS: (3)) for each participant was measured using a small radio-photoluminescence glass dosimeter mounted on lead glasses. Physicians were directed to procedure multiple radiation protection measures to evaluate their usefulness. RESULTS: (3) reduced from 207.7 to 43.2 μSv/procedure and from 21.6 to 10.2 μSv/procedure in cardiovascular internal physician and cerebrovascular physician, respectively, after the implementation of the proposed multiple radiation protection measures. The dose reduction rate of these measures was 53% (range: 37%-79%). CONCLUSIONS: The radiation doses received by the eye lenses of physicians engaged in radiology procedure may exceed the dose limits to the lens of the eye if radio-protective equipment and imaging conditions are not properly controlled. However, based on the lens equivalent dose data, the implementation of "multiple radiation protection" according to the basic principles of occupational health can ensure compliance with the new-equivalent dose limits to the lens of the eye without placing an undue burden on individual physicians or medical facilities.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: We investigated occupational dose to the lens of the eye for physicians engaged in radiology procedures. We evaluated the potential for compliance with the new-equivalent dose limits to the lens of the eye. Further, a "multiple radiation protection" protocol was proposed according to the basic principles of occupational health, and its effectiveness was estimated. METHODS: (3)) for each participant was measured using a small radio-photoluminescence glass dosimeter mounted on lead glasses. Physicians were directed to procedure multiple radiation protection measures to evaluate their usefulness. RESULTS: (3) reduced from 207.7 to 43.2 μSv/procedure and from 21.6 to 10.2 μSv/procedure in cardiovascular internal physician and cerebrovascular physician, respectively, after the implementation of the proposed multiple radiation protection measures. The dose reduction rate of these measures was 53% (range: 37%-79%). CONCLUSIONS: The radiation doses received by the eye lenses of physicians engaged in radiology procedure may exceed the dose limits to the lens of the eye if radio-protective equipment and imaging conditions are not properly controlled. However, based on the lens equivalent dose data, the implementation of "multiple radiation protection" according to the basic principles of occupational health can ensure compliance with the new-equivalent dose limits to the lens of the eye without placing an undue burden on individual physicians or medical facilities.

Key concepts: Eye lens, Radiation protection, Dosimeter, Equivalent dose, Medicine, Medical physics, Lens (geology), Protocol (science)

Related papers

Back to paper searchBrowse research topicsOriginal source
A multicenter study of radiation doses to the eye lenses of clinical physicians performing radiology procedures in Japan — Research Paper | ScholarLens