Diagnostic accuracy of wrist MRI in comparison to wrist arthroscopy regarding TFCC lesions in clinical practice

Claudia Spies, Frank Unglaub, Thomas Brückner, Lars Peter Müller, Peer Eysel, Jeffery Rau

Open full text 16 citations

Abstract

INTRODUCTION: The purpose of this study was to arthroscopically verify MRI diagnostic accuracy for triangular fibrocartilage complex (TFCC) lesions in a regular clinical environment. METHODS: A total of 859 patients' data with both preoperative MRI of the wrist and additional wrist arthroscopy were retrospectively reviewed. Two board-certified hand surgeons and one orthopaedic surgeon executed wrist arthroscopy, whereas more than 100 radiologists examined the MRI of the wrist. The accordance of TFCC lesion classification using MRI in comparison to wrist arthroscopy and diagnostic precision of the former depending on technical details were evaluated. RESULTS: Diagnostic accuracy of MRI for TFCC lesions is poor in comparison to wrist arthroscopy as the reference standard. Technical specifications for MRI of the wrist are heterogeneous among the radiologists. These parameters have not improved accuracy of TFCC evaluation at large. CONCLUSION: The accuracy of MRI in a regular clinical environment still remains inferior to wrist arthroscopy for detection of TFCC lesions. Development of a standard MRI protocol may be implemented on a regular basis and application of the Palmer classification for TFCC lesion should be sought.

About this research paper

What this paper is about

INTRODUCTION: The purpose of this study was to arthroscopically verify MRI diagnostic accuracy for triangular fibrocartilage complex (TFCC) lesions in a regular clinical environment. METHODS: A total of 859 patients' data with both preoperative MRI of the wrist and additional wrist arthroscopy were retrospectively reviewed. Two board-certified hand surgeons and one orthopaedic surgeon executed wrist arthroscopy, whereas more than 100 radiologists examined the MRI of the wrist. The accordance of TFCC lesion classification using MRI in comparison to wrist arthroscopy and diagnostic precision of the former depending on technical details were evaluated. RESULTS: Diagnostic accuracy of MRI for TFCC lesions is poor in comparison to wrist arthroscopy as the reference standard. Technical specifications for MRI of the wrist are heterogeneous among the radiologists. These parameters have not improved accuracy of TFCC evaluation at large. CONCLUSION: The accuracy of MRI in a regular clinical environment still remains inferior to wrist arthroscopy for detection of TFCC lesions. Development of a standard MRI protocol may be implemented on a regular basis and application of the Palmer classification for TFCC lesion should be sought.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

INTRODUCTION: The purpose of this study was to arthroscopically verify MRI diagnostic accuracy for triangular fibrocartilage complex (TFCC) lesions in a regular clinical environment. METHODS: A total of 859 patients' data with both preoperative MRI of the wrist and additional wrist arthroscopy were retrospectively reviewed. Two board-certified hand surgeons and one orthopaedic surgeon executed wrist arthroscopy, whereas more than 100 radiologists examined the MRI of the wrist. The accordance of TFCC lesion classification using MRI in comparison to wrist arthroscopy and diagnostic precision of the former depending on technical details were evaluated. RESULTS: Diagnostic accuracy of MRI for TFCC lesions is poor in comparison to wrist arthroscopy as the reference standard. Technical specifications for MRI of the wrist are heterogeneous among the radiologists. These parameters have not improved accuracy of TFCC evaluation at large. CONCLUSION: The accuracy of MRI in a regular clinical environment still remains inferior to wrist arthroscopy for detection of TFCC lesions. Development of a standard MRI protocol may be implemented on a regular basis and application of the Palmer classification for TFCC lesion should be sought.

Key concepts: Wrist arthroscopy, Wrist, Medicine, Arthroscopy, Orthopedic surgery, Radiology, Magnetic resonance imaging, Wrist pain

Related papers

Back to paper searchBrowse research topicsOriginal source
Diagnostic accuracy of wrist MRI in comparison to wrist arthroscopy regarding TFCC lesions in clinical practice — Research Paper | ScholarLens