2021•Medical PhysicsRequires access

The detective quantum efficiency of cadmium telluride photon‐counting x‐ray detectors in breast imaging applications

James A. Day, Jesse Tanguay

Open publisher page 9 citations

Abstract

Abstract Purpose In breast imaging applications, cadmium telluride (CdTe) photon counting x‐ray detectors (PCDs) may reduce radiation dose and enable single‐shot multi‐energy x‐ray imaging. The purpose of this work is to determine the upper limits of the detective quantum efficiency (DQE) of CdTe PCDs for x‐ray mammography and to compare them with the published DQEs of energy‐integrating detectors (EIDs) and other PCDs. Methods We calibrated and validated a Monte Carlo (MC) model of the DQE of CdTe PCDs using an XCounter CdTe PCD. Our model accounted for charge sharing, electronic noise, and charge summation logic. We used a 28 kVp Mo/Mo spectrum hardened by 3.9 cm of Lucite to optimize the detector thickness and energy threshold for pixel sizes of 50, 85, and 100 m with and without inter‐pixel charge summation logic. The figure of merit used for optimization was the integral of the DQE, which is equivalent to the detectability index for a delta function task function, which represents a high‐frequency task. Results For an electronic noise level equal to that of the XCounter, the optimal DQE(0) without charge summing was 0.74. Charge summing for charge‐sharing correction reduced DQE(0) by 14% due to an increase in electronic noise. Reducing the electronic noise to ∼0.5 keV per pixel in combination with charge summing resulted in DQE(0) 0.78 for 85 m pixels, which is approximately equal to that of a ‐Se and slot‐scanning silicon‐strip PCDs. At higher spatial frequencies, and for matched pixel sizes, the DQE was inferior to that of a ‐Se EIDs and superior to that of slot‐scanning silicon‐strip PCDs in the scan direction but inferior in the slit direction. Conclusions (1) CdTe PCDs have the potential to provide a zero‐frequency DQE equal to that of a ‐Se EIDs and slot‐scanning silicon‐strip PCDs, but this will require electronic noise levels ∼0.5 keV per pixel. (2) At mid‐to‐high spatial frequencies the DQE of CdTe PCDs may be (a) inferior to that of a ‐Se EIDs and slot‐scanning silicon‐strip PCDs in the slit direction, and (b) superior to slot‐scanning silicon‐strip PCDs in the scan direction.

About this research paper

What this paper is about

Abstract Purpose In breast imaging applications, cadmium telluride (CdTe) photon counting x‐ray detectors (PCDs) may reduce radiation dose and enable single‐shot multi‐energy x‐ray imaging. The purpose of this work is to determine the upper limits of the detective quantum efficiency (DQE) of CdTe PCDs for x‐ray mammography and to compare them with the published DQEs of energy‐integrating detectors (EIDs) and other PCDs. Methods We calibrated and validated a Monte Carlo (MC) model of the DQE of CdTe PCDs using an XCounter CdTe PCD. Our model accounted for charge sharing, electronic noise, and charge summation logic. We used a 28 kVp Mo/Mo spectrum hardened by 3.9 cm of Lucite to optimize the detector thickness and energy threshold for pixel sizes of 50, 85, and 100 m with and without inter‐pixel charge summation logic. The figure of merit used for optimization was the integral of the DQE, which is equivalent to the detectability index for a delta function task function, which represents a high‐frequency task. Results For an electronic noise level equal to that of the XCounter, the optimal DQE(0) without charge summing was 0.74. Charge summing for charge‐sharing correction reduced DQE(0) by 14% due to an increase in electronic noise. Reducing the electronic noise to ∼0.5 keV per pixel in combination with charge summing resulted in DQE(0) 0.78 for 85 m pixels, which is approximately equal to that of a ‐Se and slot‐scanning silicon‐strip PCDs. At higher spatial frequencies, and for matched pixel sizes, the DQE was inferior to that of a ‐Se EIDs and superior to that of slot‐scanning silicon‐strip PCDs in the scan direction but inferior in the slit direction. Conclusions (1) CdTe PCDs have the potential to provide a zero‐frequency DQE equal to that of a ‐Se EIDs and slot‐scanning silicon‐strip PCDs, but this will require electronic noise levels ∼0.5 keV per pixel. (2) At mid‐to‐high spatial frequencies the DQE of CdTe PCDs may be (a) inferior to that of a ‐Se EIDs and slot‐scanning silicon‐strip PCDs in the slit direction, and (b) superior to slot‐scanning silicon‐strip PCDs in the scan direction.

Why it matters

OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Purpose In breast imaging applications, cadmium telluride (CdTe) photon counting x‐ray detectors (PCDs) may reduce radiation dose and enable single‐shot multi‐energy x‐ray imaging. The purpose of this work is to determine the upper limits of the detective quantum efficiency (DQE) of CdTe PCDs for x‐ray mammography and to compare them with the published DQEs of energy‐integrating detectors (EIDs) and other PCDs. Methods We calibrated and validated a Monte Carlo (MC) model of the DQE of CdTe PCDs using an XCounter CdTe PCD. Our model accounted for charge sharing, electronic noise, and charge summation logic. We used a 28 kVp Mo/Mo spectrum hardened by 3.9 cm of Lucite to optimize the detector thickness and energy threshold for pixel sizes of 50, 85, and 100 m with and without inter‐pixel charge summation logic. The figure of merit used for optimization was the integral of the DQE, which is equivalent to the detectability index for a delta function task function, which represents a high‐frequency task. Results For an electronic noise level equal to that of the XCounter, the optimal DQE(0) without charge summing was 0.74. Charge summing for charge‐sharing correction reduced DQE(0) by 14% due to an increase in electronic noise. Reducing the electronic noise to ∼0.5 keV per pixel in combination with charge summing resulted in DQE(0) 0.78 for 85 m pixels, which is approximately equal to that of a ‐Se and slot‐scanning silicon‐strip PCDs. At higher spatial frequencies, and for matched pixel sizes, the DQE was inferior to that of a ‐Se EIDs and superior to that of slot‐scanning silicon‐strip PCDs in the scan direction but inferior in the slit direction. Conclusions (1) CdTe PCDs have the potential to provide a zero‐frequency DQE equal to that of a ‐Se EIDs and slot‐scanning silicon‐strip PCDs, but this will require electronic noise levels ∼0.5 keV per pixel. (2) At mid‐to‐high spatial frequencies the DQE of CdTe PCDs may be (a) inferior to that of a ‐Se EIDs and slot‐scanning silicon‐strip PCDs in the slit direction, and (b) superior to slot‐scanning silicon‐strip PCDs in the scan direction.

Key concepts: Detective quantum efficiency, Charge sharing, Physics, Optics, Detector, X-ray detector, Photon, Figure of merit

Related papers

Back to paper searchBrowse research topicsOriginal source
The detective quantum efficiency of cadmium telluride photon‐counting x‐ray detectors in breast imaging applications — Research Paper | ScholarLens