1990PubMedRequires access

Practical value of echo Doppler evaluation of aortic and mitral stenosis: a comparative study with cardiac catheterization.

J Bitar, Lori Douthat, Mohsin Alam, H S Rosman, Mark P. Lebeis, Stanley Goldstein, F Khaja

Open publisher page 4 citations

Abstract

This retrospective analysis compares data derived by echocardiography and cardiac catheterization in the evaluation of aortic and mitral valve stenosis. Sixty-seven patients, aged 69 +/- 12 years, underwent 76 catheterization procedures. In all studies the Doppler recording was technically adequate. In 64 studies of patients with aortic stenosis, correlation was good between the gradient obtained at catheterization (peak 51 +/- 28 mm Hg, mean 48 +/- 24 mm Hg) and the Doppler gradient (peak 73 +/- 29 mm Hg, mean 41 +/- 17 mm Hg) (R = 0.78 peak, 0.77 mean). In 15 studies the aortic valve area, 0.8 +/- 0.2 cm2, calculated by the simplified continuity equation, correlated well with the catheterization valve area, 0.7 +/- 0.3 cm2, calculated by the Gorlin equation (R = 0.80). In 14 studies in mitral stenosis patients, the mean gradient at catheterization was 11 +/- 5 mm Hg compared to the Doppler gradient of 8 +/- 4 mm Hg (R = 0.58). The mitral valve area was 1.1 +/- 0.3 cm2 by the Gorlin equation and 1.2 +/- 0.3 cm2 by echo Doppler, using pressure half-time. When cardiac rhythm, the presence and severity of regurgitation, and the cardiac index were analyzed, none was shown to have demonstrable influence on the accuracy of the Doppler study. Doppler echocardiography can be used reliably to assess valvular stenosis in a clinical, noninvasive laboratory where routine tests are performed and interpreted by more than one individual.

About this research paper

What this paper is about

This retrospective analysis compares data derived by echocardiography and cardiac catheterization in the evaluation of aortic and mitral valve stenosis. Sixty-seven patients, aged 69 +/- 12 years, underwent 76 catheterization procedures. In all studies the Doppler recording was technically adequate. In 64 studies of patients with aortic stenosis, correlation was good between the gradient obtained at catheterization (peak 51 +/- 28 mm Hg, mean 48 +/- 24 mm Hg) and the Doppler gradient (peak 73 +/- 29 mm Hg, mean 41 +/- 17 mm Hg) (R = 0.78 peak, 0.77 mean). In 15 studies the aortic valve area, 0.8 +/- 0.2 cm2, calculated by the simplified continuity equation, correlated well with the catheterization valve area, 0.7 +/- 0.3 cm2, calculated by the Gorlin equation (R = 0.80). In 14 studies in mitral stenosis patients, the mean gradient at catheterization was 11 +/- 5 mm Hg compared to the Doppler gradient of 8 +/- 4 mm Hg (R = 0.58). The mitral valve area was 1.1 +/- 0.3 cm2 by the Gorlin equation and 1.2 +/- 0.3 cm2 by echo Doppler, using pressure half-time. When cardiac rhythm, the presence and severity of regurgitation, and the cardiac index were analyzed, none was shown to have demonstrable influence on the accuracy of the Doppler study. Doppler echocardiography can be used reliably to assess valvular stenosis in a clinical, noninvasive laboratory where routine tests are performed and interpreted by more than one individual.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This retrospective analysis compares data derived by echocardiography and cardiac catheterization in the evaluation of aortic and mitral valve stenosis. Sixty-seven patients, aged 69 +/- 12 years, underwent 76 catheterization procedures. In all studies the Doppler recording was technically adequate. In 64 studies of patients with aortic stenosis, correlation was good between the gradient obtained at catheterization (peak 51 +/- 28 mm Hg, mean 48 +/- 24 mm Hg) and the Doppler gradient (peak 73 +/- 29 mm Hg, mean 41 +/- 17 mm Hg) (R = 0.78 peak, 0.77 mean). In 15 studies the aortic valve area, 0.8 +/- 0.2 cm2, calculated by the simplified continuity equation, correlated well with the catheterization valve area, 0.7 +/- 0.3 cm2, calculated by the Gorlin equation (R = 0.80). In 14 studies in mitral stenosis patients, the mean gradient at catheterization was 11 +/- 5 mm Hg compared to the Doppler gradient of 8 +/- 4 mm Hg (R = 0.58). The mitral valve area was 1.1 +/- 0.3 cm2 by the Gorlin equation and 1.2 +/- 0.3 cm2 by echo Doppler, using pressure half-time. When cardiac rhythm, the presence and severity of regurgitation, and the cardiac index were analyzed, none was shown to have demonstrable influence on the accuracy of the Doppler study. Doppler echocardiography can be used reliably to assess valvular stenosis in a clinical, noninvasive laboratory where routine tests are performed and interpreted by more than one individual.

Key concepts: Cardiac catheterization, Medicine, Stenosis, Cardiology, Internal medicine, Doppler echocardiography, Doppler effect, Aortic valve

Related papers

Back to paper searchBrowse research topicsOriginal source
Practical value of echo Doppler evaluation of aortic and mitral stenosis: a comparative study with cardiac catheterization. — Research Paper | ScholarLens