2011Journal of the South China Agricultural UniversityRequires access

Determination of Diazinon Residues in Milk by Gas Chromatography

Ran Ao, Zeng ZhenLing, Yu JingXian, Shen XiangGuang

Open publisher page 0 citations

Abstract

A gas chromatographic method was developed for the determination of diazinon residues in milk.Samples dissolved in acetone were extracted with n-hexane,cleaned with neutral alumina column,and determined by gas chromatography(flame photometric detector) after volume measurement with acetone.The recoveries of the determination were 73.4%-96.2%.The values of intra and inter-assay RSD were in the range of 3.5%-9.1% and 4.9%-7.5%,respectively.The linear correlation coefficient was 0.999 9.The detection limit was 2.0 μg·kg-1 and the limit of quantitation remained as 5.0 μg·kg-1.

About this research paper

What this paper is about

A gas chromatographic method was developed for the determination of diazinon residues in milk.Samples dissolved in acetone were extracted with n-hexane,cleaned with neutral alumina column,and determined by gas chromatography(flame photometric detector) after volume measurement with acetone.The recoveries of the determination were 73.4%-96.2%.The values of intra and inter-assay RSD were in the range of 3.5%-9.1% and 4.9%-7.5%,respectively.The linear correlation coefficient was 0.999 9.The detection limit was 2.0 μg·kg-1 and the limit of quantitation remained as 5.0 μg·kg-1.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A gas chromatographic method was developed for the determination of diazinon residues in milk.Samples dissolved in acetone were extracted with n-hexane,cleaned with neutral alumina column,and determined by gas chromatography(flame photometric detector) after volume measurement with acetone.The recoveries of the determination were 73.4%-96.2%.The values of intra and inter-assay RSD were in the range of 3.5%-9.1% and 4.9%-7.5%,respectively.The linear correlation coefficient was 0.999 9.The detection limit was 2.0 μg·kg-1 and the limit of quantitation remained as 5.0 μg·kg-1.

Key concepts: Chromatography, Diazinon, Detection limit, Gas chromatography, Acetone, Chemistry, Electron capture detector, Hexane

Related papers

Back to paper searchBrowse research topicsOriginal source