[Determination of salylic acid, syringic acid, benzoic acid and anthranilic acid in Radix Isatidis by HPCE].
Xiaoxue Wang, Wenjie Zheng, Guoxiang Xie, Mingfeng Qiu, Wei Jia
Abstract
Xiaoxue Wang, Wenjie Zheng, Guoxiang Xie, Mingfeng Qiu, Wei Jia
Abstract
OBJECTIVE: To develop a simple and rapid capillary electrophoresis (CE) method for the separation and determination of four active organic acids including salicylic acid, syringic acid, benzoic acid, and anthranilic acid in Radix Isatidis. METHOD: The HPCE system consisted of a fused-silica capillary column of 47.3 cm (38.3 cm to the detector) x50 microm i.d. and a mixture ofacetonitrile-borate buffer (15% acetonitrile, 25 mmol L(-1) borate, 15 mmol L(-1) beta-CD, pH 9.10) solution as the operating buffer. The applied voltage was 11.5 kV and the UV detection was set at 220 nm. The effects of the applied voltage, detection wavelength, and the pH of buffer, the concentration of buffer, acetonitrile and beta-CD were investigated. RESULT: The linear calibration rang was 3.0-90 mg L(-1) (r=0.9994) for salylic acid, 4.0-120 mg L(-1) (r=0.9995) for syringic acid, 2.0-60 mg L(-1) (r=0.9998) for benzoic acid and 5.0-100 mg L(-1) (r=0.9992) for anthranilic acid. The recoveries of salylic acid, syringic acid, benzoic acid and anthranilic acid were 95.9%-102.6%, 98.6%-103.4%, 98.7%-104.1%, 96.1%-104.3% respectively. The detection limits of salylic acid, syringic acid, benzoic acid and anthranilic acid were 0.7, 1.1, 1.2 and 1.5 mg L(-1), respectively.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To develop a simple and rapid capillary electrophoresis (CE) method for the separation and determination of four active organic acids including salicylic acid, syringic acid, benzoic acid, and anthranilic acid in Radix Isatidis. METHOD: The HPCE system consisted of a fused-silica capillary column of 47.3 cm (38.3 cm to the detector) x50 microm i.d. and a mixture ofacetonitrile-borate buffer (15% acetonitrile, 25 mmol L(-1) borate, 15 mmol L(-1) beta-CD, pH 9.10) solution as the operating buffer. The applied voltage was 11.5 kV and the UV detection was set at 220 nm. The effects of the applied voltage, detection wavelength, and the pH of buffer, the concentration of buffer, acetonitrile and beta-CD were investigated. RESULT: The linear calibration rang was 3.0-90 mg L(-1) (r=0.9994) for salylic acid, 4.0-120 mg L(-1) (r=0.9995) for syringic acid, 2.0-60 mg L(-1) (r=0.9998) for benzoic acid and 5.0-100 mg L(-1) (r=0.9992) for anthranilic acid. The recoveries of salylic acid, syringic acid, benzoic acid and anthranilic acid were 95.9%-102.6%, 98.6%-103.4%, 98.7%-104.1%, 96.1%-104.3% respectively. The detection limits of salylic acid, syringic acid, benzoic acid and anthranilic acid were 0.7, 1.1, 1.2 and 1.5 mg L(-1), respectively.
Key concepts: Syringic acid, Chemistry, Benzoic acid, Anthranilic acid, Chromatography, Salicylic acid, Capillary electrophoresis, Detection limit