2021•PubMedRequires access

[Air-Kerma Standard for Mammography X-Ray in Japan: Progress and Prospects].

Takahiro Tanaka

Open publisher page 0 citations

Abstract

In Japan, mammography was introduced in 2000 for the early detection of breast cancer. In quality control of mammography, dosimetry is one of the most important items. For accurate dosimetry, calibration of dosimeters is necessary because radiation quality (target-filter combination) of mammography x-ray is different from that of general radiography. Therefore, development of dosimetry standard based on radiation quality of mammography x-ray was required. AIST/NMIJ developed an air-kerma standard for mammography x-rays and started its dissemination in 2009. Since then, the air-kerma standard has been extended to various radiation qualities that have come to be used in digital mammography. In this paper, an overview of the air-kerma standard for mammography x-ray together with a future plan is briefly presented.

About this research paper

What this paper is about

In Japan, mammography was introduced in 2000 for the early detection of breast cancer. In quality control of mammography, dosimetry is one of the most important items. For accurate dosimetry, calibration of dosimeters is necessary because radiation quality (target-filter combination) of mammography x-ray is different from that of general radiography. Therefore, development of dosimetry standard based on radiation quality of mammography x-ray was required. AIST/NMIJ developed an air-kerma standard for mammography x-rays and started its dissemination in 2009. Since then, the air-kerma standard has been extended to various radiation qualities that have come to be used in digital mammography. In this paper, an overview of the air-kerma standard for mammography x-ray together with a future plan is briefly presented.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In Japan, mammography was introduced in 2000 for the early detection of breast cancer. In quality control of mammography, dosimetry is one of the most important items. For accurate dosimetry, calibration of dosimeters is necessary because radiation quality (target-filter combination) of mammography x-ray is different from that of general radiography. Therefore, development of dosimetry standard based on radiation quality of mammography x-ray was required. AIST/NMIJ developed an air-kerma standard for mammography x-rays and started its dissemination in 2009. Since then, the air-kerma standard has been extended to various radiation qualities that have come to be used in digital mammography. In this paper, an overview of the air-kerma standard for mammography x-ray together with a future plan is briefly presented.

Key concepts: Kerma, Mammography, Dosimetry, Medical physics, Digital mammography, Dosimeter, Medicine, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
[Air-Kerma Standard for Mammography X-Ray in Japan: Progress and Prospects]. — Research Paper | ScholarLens