2021Journal of the Medical Association of ThailandRequires access

Cycloplegic Refraction in Myopic Children with Brown Irises: Time of Maximum Cycloplegia and Difference between Retinoscopy and Autorefraction

Author information unavailable

Open publisher page 0 citations

Abstract

Objective: To evaluate time of maximum cycloplegia in myopic children with brown irises and to study differences between refractive error after maximum cycloplegia measured by retinoscopy and autorefraction. Materials and Methods: The present study was a prospective descriptive study included myopic children with brown irises aged 5 to 14 years. Cycloplegic refraction was performed using cyclopentolate 1%, three times, ten minutes apart. Refractive error was measured by autorefraction before and at 30, 40, 50, 60, 70, and 80 minutes after the first instillation of cyclopentolate. Finally, retinoscopy was performed by a single examiner at 80 minutes. Time of maximum cycloplegia was determined from the time point at which the 95% confidence interval of the differences between the mean spherical equivalent (SE) at each point and its final value at 80 minutes was reached and remained within the equivalence limit (±0.25 D). Difference between SE of retinoscopy and autorefraction was evaluated. Results: Sixty-eight children were recruited. The mean age was 10.5 years (SD 2.4). Thirty-seven children were male (54%). The time of maximum cycloplegia was 30 minutes after the first instillation of cyclopentolate. At 80 minutes, the degree of myopia measured by autorefraction was significantly higher compared to those measured by retinoscopy (p<0.001, mean difference 0.26 D). Conclusion: Time of maximum cycloplegia in myopic children with brown irises was 30 minutes after the first instillation of cyclopentolate. Even when the maximum cycloplegia was reached, the degree of myopia measured by autorefraction was higher than that measured by retinoscopy. Keywords: Cycloplegic refraction, Cyclopentolate, Cycloplegia, Myopia, Myopia in children, Retinoscopy, Autorefraction

About this research paper

What this paper is about

Objective: To evaluate time of maximum cycloplegia in myopic children with brown irises and to study differences between refractive error after maximum cycloplegia measured by retinoscopy and autorefraction. Materials and Methods: The present study was a prospective descriptive study included myopic children with brown irises aged 5 to 14 years. Cycloplegic refraction was performed using cyclopentolate 1%, three times, ten minutes apart. Refractive error was measured by autorefraction before and at 30, 40, 50, 60, 70, and 80 minutes after the first instillation of cyclopentolate. Finally, retinoscopy was performed by a single examiner at 80 minutes. Time of maximum cycloplegia was determined from the time point at which the 95% confidence interval of the differences between the mean spherical equivalent (SE) at each point and its final value at 80 minutes was reached and remained within the equivalence limit (±0.25 D). Difference between SE of retinoscopy and autorefraction was evaluated. Results: Sixty-eight children were recruited. The mean age was 10.5 years (SD 2.4). Thirty-seven children were male (54%). The time of maximum cycloplegia was 30 minutes after the first instillation of cyclopentolate. At 80 minutes, the degree of myopia measured by autorefraction was significantly higher compared to those measured by retinoscopy (p<0.001, mean difference 0.26 D). Conclusion: Time of maximum cycloplegia in myopic children with brown irises was 30 minutes after the first instillation of cyclopentolate. Even when the maximum cycloplegia was reached, the degree of myopia measured by autorefraction was higher than that measured by retinoscopy. Keywords: Cycloplegic refraction, Cyclopentolate, Cycloplegia, Myopia, Myopia in children, Retinoscopy, Autorefraction

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To evaluate time of maximum cycloplegia in myopic children with brown irises and to study differences between refractive error after maximum cycloplegia measured by retinoscopy and autorefraction. Materials and Methods: The present study was a prospective descriptive study included myopic children with brown irises aged 5 to 14 years. Cycloplegic refraction was performed using cyclopentolate 1%, three times, ten minutes apart. Refractive error was measured by autorefraction before and at 30, 40, 50, 60, 70, and 80 minutes after the first instillation of cyclopentolate. Finally, retinoscopy was performed by a single examiner at 80 minutes. Time of maximum cycloplegia was determined from the time point at which the 95% confidence interval of the differences between the mean spherical equivalent (SE) at each point and its final value at 80 minutes was reached and remained within the equivalence limit (±0.25 D). Difference between SE of retinoscopy and autorefraction was evaluated. Results: Sixty-eight children were recruited. The mean age was 10.5 years (SD 2.4). Thirty-seven children were male (54%). The time of maximum cycloplegia was 30 minutes after the first instillation of cyclopentolate. At 80 minutes, the degree of myopia measured by autorefraction was significantly higher compared to those measured by retinoscopy (p<0.001, mean difference 0.26 D). Conclusion: Time of maximum cycloplegia in myopic children with brown irises was 30 minutes after the first instillation of cyclopentolate. Even when the maximum cycloplegia was reached, the degree of myopia measured by autorefraction was higher than that measured by retinoscopy. Keywords: Cycloplegic refraction, Cyclopentolate, Cycloplegia, Myopia, Myopia in children, Retinoscopy, Autorefraction

Key concepts: Cycloplegia, Retinoscopy, Cyclopentolate, Mean difference, Refractive error, Optometry, Significant difference, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Cycloplegic Refraction in Myopic Children with Brown Irises: Time of Maximum Cycloplegia and Difference between Retinoscopy and Autorefraction — Research Paper | ScholarLens