Flexible Fault Current Adaptation Features of a Novel DC Circuit Breaker Assisted by Superconducting Fault Current Limiters
Hongxu Li, Bin Xiang, Xuedong Wang, Siyi Li, Siyuan Liu, Yingsan Geng, Zhiyuan Liu, Jianhua Wang
Abstract
Hongxu Li, Bin Xiang, Xuedong Wang, Siyi Li, Siyuan Liu, Yingsan Geng, Zhiyuan Liu, Jianhua Wang
Abstract
The high di/dtbefore zero-crossings easily leads to delayed or failed operations for the active current injection mechanical DC circuit breaker, especially for small direct current interruptions. The pre-charging process also makes this type of circuit breaker hard to realize repeat operations economically in the high voltage DC system. This paper proposes a novel DC circuit breaker and its design method that deeply coordinating a superconducting fault current limiter with the active current injection DC circuit breaker. This method significantly reduces di/dtbefore current zero-crossings and enables repeat operations economically. Besides limiting fault currents, the superconducting fault current limiter also charges the resonance capacitor flexibly in the circuit breaker, realizing the injected reverse current keep a constant proportion to the arbitrary fault current. Validations of the flexible capacitor charge and repeat operations are made by simulation and low voltage experiments. The charging times are within 2.5 ms and the reverse current keeps 1.2 to 1.7 times over the fault current under arbitrary conditions. Di/dtat current zero is reduced by 80% under 30% of rated interruption capacity. Flexible capacitor charge experiments are consistent with the simulation design. The superconducting tapes can recover within 300 ms to support repeat operations.
OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The high di/dtbefore zero-crossings easily leads to delayed or failed operations for the active current injection mechanical DC circuit breaker, especially for small direct current interruptions. The pre-charging process also makes this type of circuit breaker hard to realize repeat operations economically in the high voltage DC system. This paper proposes a novel DC circuit breaker and its design method that deeply coordinating a superconducting fault current limiter with the active current injection DC circuit breaker. This method significantly reduces di/dtbefore current zero-crossings and enables repeat operations economically. Besides limiting fault currents, the superconducting fault current limiter also charges the resonance capacitor flexibly in the circuit breaker, realizing the injected reverse current keep a constant proportion to the arbitrary fault current. Validations of the flexible capacitor charge and repeat operations are made by simulation and low voltage experiments. The charging times are within 2.5 ms and the reverse current keeps 1.2 to 1.7 times over the fault current under arbitrary conditions. Di/dtat current zero is reduced by 80% under 30% of rated interruption capacity. Flexible capacitor charge experiments are consistent with the simulation design. The superconducting tapes can recover within 300 ms to support repeat operations.
Key concepts: Circuit breaker, Fault current limiter, Electrical engineering, Fault (geology), Capacitor, Current limiting, Current (fluid), Limiter