2021IEEE Transactions on Power DeliveryRequires access

Flexible Fault Current Adaptation Features of a Novel DC Circuit Breaker Assisted by Superconducting Fault Current Limiters

Hongxu Li, Bin Xiang, Xuedong Wang, Siyi Li, Siyuan Liu, Yingsan Geng, Zhiyuan Liu, Jianhua Wang

Open publisher page 8 citations

Abstract

The high di/dtbefore zero-crossings easily leads to delayed or failed operations for the active current injection mechanical DC circuit breaker, especially for small direct current interruptions. The pre-charging process also makes this type of circuit breaker hard to realize repeat operations economically in the high voltage DC system. This paper proposes a novel DC circuit breaker and its design method that deeply coordinating a superconducting fault current limiter with the active current injection DC circuit breaker. This method significantly reduces di/dtbefore current zero-crossings and enables repeat operations economically. Besides limiting fault currents, the superconducting fault current limiter also charges the resonance capacitor flexibly in the circuit breaker, realizing the injected reverse current keep a constant proportion to the arbitrary fault current. Validations of the flexible capacitor charge and repeat operations are made by simulation and low voltage experiments. The charging times are within 2.5 ms and the reverse current keeps 1.2 to 1.7 times over the fault current under arbitrary conditions. Di/dtat current zero is reduced by 80% under 30% of rated interruption capacity. Flexible capacitor charge experiments are consistent with the simulation design. The superconducting tapes can recover within 300 ms to support repeat operations.

About this research paper

What this paper is about

The high di/dtbefore zero-crossings easily leads to delayed or failed operations for the active current injection mechanical DC circuit breaker, especially for small direct current interruptions. The pre-charging process also makes this type of circuit breaker hard to realize repeat operations economically in the high voltage DC system. This paper proposes a novel DC circuit breaker and its design method that deeply coordinating a superconducting fault current limiter with the active current injection DC circuit breaker. This method significantly reduces di/dtbefore current zero-crossings and enables repeat operations economically. Besides limiting fault currents, the superconducting fault current limiter also charges the resonance capacitor flexibly in the circuit breaker, realizing the injected reverse current keep a constant proportion to the arbitrary fault current. Validations of the flexible capacitor charge and repeat operations are made by simulation and low voltage experiments. The charging times are within 2.5 ms and the reverse current keeps 1.2 to 1.7 times over the fault current under arbitrary conditions. Di/dtat current zero is reduced by 80% under 30% of rated interruption capacity. Flexible capacitor charge experiments are consistent with the simulation design. The superconducting tapes can recover within 300 ms to support repeat operations.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The high di/dtbefore zero-crossings easily leads to delayed or failed operations for the active current injection mechanical DC circuit breaker, especially for small direct current interruptions. The pre-charging process also makes this type of circuit breaker hard to realize repeat operations economically in the high voltage DC system. This paper proposes a novel DC circuit breaker and its design method that deeply coordinating a superconducting fault current limiter with the active current injection DC circuit breaker. This method significantly reduces di/dtbefore current zero-crossings and enables repeat operations economically. Besides limiting fault currents, the superconducting fault current limiter also charges the resonance capacitor flexibly in the circuit breaker, realizing the injected reverse current keep a constant proportion to the arbitrary fault current. Validations of the flexible capacitor charge and repeat operations are made by simulation and low voltage experiments. The charging times are within 2.5 ms and the reverse current keeps 1.2 to 1.7 times over the fault current under arbitrary conditions. Di/dtat current zero is reduced by 80% under 30% of rated interruption capacity. Flexible capacitor charge experiments are consistent with the simulation design. The superconducting tapes can recover within 300 ms to support repeat operations.

Key concepts: Circuit breaker, Fault current limiter, Electrical engineering, Fault (geology), Capacitor, Current limiting, Current (fluid), Limiter

Related papers

Back to paper searchBrowse research topicsOriginal source
Flexible Fault Current Adaptation Features of a Novel DC Circuit Breaker Assisted by Superconducting Fault Current Limiters — Research Paper | ScholarLens