2010Unpublished venueRequires access

Transient Cooling Load Simulation of aMechanical Workshop at UTP Using TRNSYS

Syed Ihtsham Ul-Haq Gilani, Tri Bhaskoro Petrus

Open publisher page 0 citations

Abstract

One of the major energy consumers in any commercial building, in hot and humid area is the air conditioning system.Therefore matching between air conditioning (AC) systems strategies with the cooling load characteristic is crucial to ensure effectiveness. Previous researches have been done to determine cooling load characteristic for office and residential building. However, same research for mechanical workshop is rare and still need further development. Due to that the paper aims to provide transient cooling load characteristic for mechanical workshop with large window glazing area through simulation using TRNSYS. The transient cooling load characteristics in the workshop during off-peak and peak period were presented. The results showed that the major contributor to the cooling load was heat gain from building envelope which was counted up to 58.54%% of the total cooling load in a year. The result also implied that cooling energy wasted during peak and off-peak period was approximately 50% of the total cooling load. Solutions to reduce the cooling load and cooling energy wasted using shading devices, thermal mass, and adjustable room temperature set point were also discussed and presented. The result showed that the AC system with adjustable room temperature set point reduced the cooling load by 42.2%.

About this research paper

What this paper is about

One of the major energy consumers in any commercial building, in hot and humid area is the air conditioning system.Therefore matching between air conditioning (AC) systems strategies with the cooling load characteristic is crucial to ensure effectiveness. Previous researches have been done to determine cooling load characteristic for office and residential building. However, same research for mechanical workshop is rare and still need further development. Due to that the paper aims to provide transient cooling load characteristic for mechanical workshop with large window glazing area through simulation using TRNSYS. The transient cooling load characteristics in the workshop during off-peak and peak period were presented. The results showed that the major contributor to the cooling load was heat gain from building envelope which was counted up to 58.54%% of the total cooling load in a year. The result also implied that cooling energy wasted during peak and off-peak period was approximately 50% of the total cooling load. Solutions to reduce the cooling load and cooling energy wasted using shading devices, thermal mass, and adjustable room temperature set point were also discussed and presented. The result showed that the AC system with adjustable room temperature set point reduced the cooling load by 42.2%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

One of the major energy consumers in any commercial building, in hot and humid area is the air conditioning system.Therefore matching between air conditioning (AC) systems strategies with the cooling load characteristic is crucial to ensure effectiveness. Previous researches have been done to determine cooling load characteristic for office and residential building. However, same research for mechanical workshop is rare and still need further development. Due to that the paper aims to provide transient cooling load characteristic for mechanical workshop with large window glazing area through simulation using TRNSYS. The transient cooling load characteristics in the workshop during off-peak and peak period were presented. The results showed that the major contributor to the cooling load was heat gain from building envelope which was counted up to 58.54%% of the total cooling load in a year. The result also implied that cooling energy wasted during peak and off-peak period was approximately 50% of the total cooling load. Solutions to reduce the cooling load and cooling energy wasted using shading devices, thermal mass, and adjustable room temperature set point were also discussed and presented. The result showed that the AC system with adjustable room temperature set point reduced the cooling load by 42.2%.

Key concepts: TRNSYS, Cooling load, Glazing, Air conditioning, Heat load, Transient (computer programming), Water cooling, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Transient Cooling Load Simulation of aMechanical Workshop at UTP Using TRNSYS — Research Paper | ScholarLens