2021Applied SciencesOpen access

Experimental Investigation of the Cooling Effect Generated by a Heat Sink Integrated Thermoelectric-Based U-Shaped Air-Conditioning System

Yesha Patel, Abu Raihan Mohammad Siddique, Mohammad Reza Mohaghegh, Syeda Humaira Tasnim, Shohel Mahmud

Open full text 8 citations

Abstract

Over the past years, thermoelectric refrigeration has attracted considerable attention due to its compact size, reliability, and environmental friendliness. Traditional refrigeration systems use greenhouse gases, which significantly impacts our environment. Therefore, in this work, a thermoelectric cooler prototype refrigeration system, a solid-state device causing no harm to the environment, was constructed and tested experimentally. A heat sink was attached to the cold side of the thermoelectric cooler (TEC) to cool the air passing through the heat sink. In contrast, a cold plate was attached to the hot side of TEC to remove the generated heat with the help of the liquid circulating in the aluminium cold plate. Experiments were carried out by varying parameters such as input current to the TEC module, inlet air flow rate, water flow rate through the cold plate, etc. The experimental results indicate that the cooling effect is increased by approximately 40%, increasing current from 2A to 8A. However, the cooling effect was decreased with increasing inlet airflow rate by 58% when airflow rate increased from 2.25 m/s to 3.55 m/s. However, the system performance shows approximately 35% increment with an increase in fan speed. Furthermore, a decrease in the water flow rate from 3.04 L/m to 1.80 L/m showed a slight increment in the cooling by 15%.

Open-access reader

About this research paper

What this paper is about

Over the past years, thermoelectric refrigeration has attracted considerable attention due to its compact size, reliability, and environmental friendliness. Traditional refrigeration systems use greenhouse gases, which significantly impacts our environment. Therefore, in this work, a thermoelectric cooler prototype refrigeration system, a solid-state device causing no harm to the environment, was constructed and tested experimentally. A heat sink was attached to the cold side of the thermoelectric cooler (TEC) to cool the air passing through the heat sink. In contrast, a cold plate was attached to the hot side of TEC to remove the generated heat with the help of the liquid circulating in the aluminium cold plate. Experiments were carried out by varying parameters such as input current to the TEC module, inlet air flow rate, water flow rate through the cold plate, etc. The experimental results indicate that the cooling effect is increased by approximately 40%, increasing current from 2A to 8A. However, the cooling effect was decreased with increasing inlet airflow rate by 58% when airflow rate increased from 2.25 m/s to 3.55 m/s. However, the system performance shows approximately 35% increment with an increase in fan speed. Furthermore, a decrease in the water flow rate from 3.04 L/m to 1.80 L/m showed a slight increment in the cooling by 15%.

Why it matters

OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Over the past years, thermoelectric refrigeration has attracted considerable attention due to its compact size, reliability, and environmental friendliness. Traditional refrigeration systems use greenhouse gases, which significantly impacts our environment. Therefore, in this work, a thermoelectric cooler prototype refrigeration system, a solid-state device causing no harm to the environment, was constructed and tested experimentally. A heat sink was attached to the cold side of the thermoelectric cooler (TEC) to cool the air passing through the heat sink. In contrast, a cold plate was attached to the hot side of TEC to remove the generated heat with the help of the liquid circulating in the aluminium cold plate. Experiments were carried out by varying parameters such as input current to the TEC module, inlet air flow rate, water flow rate through the cold plate, etc. The experimental results indicate that the cooling effect is increased by approximately 40%, increasing current from 2A to 8A. However, the cooling effect was decreased with increasing inlet airflow rate by 58% when airflow rate increased from 2.25 m/s to 3.55 m/s. However, the system performance shows approximately 35% increment with an increase in fan speed. Furthermore, a decrease in the water flow rate from 3.04 L/m to 1.80 L/m showed a slight increment in the cooling by 15%.

Key concepts: Thermoelectric cooling, TEC, Airflow, Refrigeration, Environmental science, Heat sink, Thermoelectric effect, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental Investigation of the Cooling Effect Generated by a Heat Sink Integrated Thermoelectric-Based U-Shaped Air-Conditioning System — Research Paper | ScholarLens