PERFORMANCE EVALUATION OF NUCLEATED RED BLOOD CELL (NRBC) COUNT USING A FULLY AUTOMATED HAEMATOLOGY ANALYZER VERSUS MANUAL COUNTING

Tanweer Ahmed, Asad Mahmood, Nasir Uddin, Helen Mary Robert, Muhammad Ashraf, Usman Tahir Swati

Open full text 2 citations

Abstract

Objective: To evaluate the performance of Nucleated RBC (NRBC) Count using a fully automated haematology analyzer versus manual counting. Study Design: Cross-Sectional Study. Place and Duration of Study: Department of Hematology, Armed Forces Institute of Pathology, from Sep 2019-Jun 2020. Methodology: Routine fresh whole blood samples were run on Sysmex XN-3000 automated haematology analyzer and 384 samples with results of ≥0.1% Nucleated red blood cells were included in this study. Manual NRBC counting was carried out twice on Leishman-stained peripheral blood smears from all 384 samples. Comparison between manual and automated nucleated red blood cell counting methods was statistically analyzed through linear regression analysis & coefficient correlation. The degree of agreement between two methods was analyzed through Bland-Altman plot. Finally, concordance between the two methods was also analyzed at 5 different ranges of nucleated red blood cells. Results: Linear regression analysis revealed a (r2) value of 0.97. Regression equation was calculated as XN = 0.76MC ± 1.28, with 95% limits of agreement between ± 40.42% and -24.47%. A mean bias of 7.97% was demonstrated through Bland-Altman plot. Concordance analysis revealed a concordance rate of 93.74% (360/384). Nucleated red blood cell counting between two methods were more concordant when nucleated red blood cell counts were <200%. Conclusion: Nucleated red blood cells counting by XN-3000 automated hematology analyzer is statistically comparable to manual nucleated red blood cell counting. We suggest that automated counting can be adopted in routine hematology laboratory as a replacement of manual NRBC counting.

Open-access reader

About this research paper

What this paper is about

Objective: To evaluate the performance of Nucleated RBC (NRBC) Count using a fully automated haematology analyzer versus manual counting. Study Design: Cross-Sectional Study. Place and Duration of Study: Department of Hematology, Armed Forces Institute of Pathology, from Sep 2019-Jun 2020. Methodology: Routine fresh whole blood samples were run on Sysmex XN-3000 automated haematology analyzer and 384 samples with results of ≥0.1% Nucleated red blood cells were included in this study. Manual NRBC counting was carried out twice on Leishman-stained peripheral blood smears from all 384 samples. Comparison between manual and automated nucleated red blood cell counting methods was statistically analyzed through linear regression analysis & coefficient correlation. The degree of agreement between two methods was analyzed through Bland-Altman plot. Finally, concordance between the two methods was also analyzed at 5 different ranges of nucleated red blood cells. Results: Linear regression analysis revealed a (r2) value of 0.97. Regression equation was calculated as XN = 0.76MC ± 1.28, with 95% limits of agreement between ± 40.42% and -24.47%. A mean bias of 7.97% was demonstrated through Bland-Altman plot. Concordance analysis revealed a concordance rate of 93.74% (360/384). Nucleated red blood cell counting between two methods were more concordant when nucleated red blood cell counts were <200%. Conclusion: Nucleated red blood cells counting by XN-3000 automated hematology analyzer is statistically comparable to manual nucleated red blood cell counting. We suggest that automated counting can be adopted in routine hematology laboratory as a replacement of manual NRBC counting.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To evaluate the performance of Nucleated RBC (NRBC) Count using a fully automated haematology analyzer versus manual counting. Study Design: Cross-Sectional Study. Place and Duration of Study: Department of Hematology, Armed Forces Institute of Pathology, from Sep 2019-Jun 2020. Methodology: Routine fresh whole blood samples were run on Sysmex XN-3000 automated haematology analyzer and 384 samples with results of ≥0.1% Nucleated red blood cells were included in this study. Manual NRBC counting was carried out twice on Leishman-stained peripheral blood smears from all 384 samples. Comparison between manual and automated nucleated red blood cell counting methods was statistically analyzed through linear regression analysis & coefficient correlation. The degree of agreement between two methods was analyzed through Bland-Altman plot. Finally, concordance between the two methods was also analyzed at 5 different ranges of nucleated red blood cells. Results: Linear regression analysis revealed a (r2) value of 0.97. Regression equation was calculated as XN = 0.76MC ± 1.28, with 95% limits of agreement between ± 40.42% and -24.47%. A mean bias of 7.97% was demonstrated through Bland-Altman plot. Concordance analysis revealed a concordance rate of 93.74% (360/384). Nucleated red blood cell counting between two methods were more concordant when nucleated red blood cell counts were <200%. Conclusion: Nucleated red blood cells counting by XN-3000 automated hematology analyzer is statistically comparable to manual nucleated red blood cell counting. We suggest that automated counting can be adopted in routine hematology laboratory as a replacement of manual NRBC counting.

Key concepts: Hematology analyzer, Nucleated Red Blood Cell, Concordance, Cell counting, Medicine, Hematology, Nuclear medicine, Red blood cell

Related papers

Back to paper searchBrowse research topicsOriginal source
PERFORMANCE EVALUATION OF NUCLEATED RED BLOOD CELL (NRBC) COUNT USING A FULLY AUTOMATED HAEMATOLOGY ANALYZER VERSUS MANUAL COUNTING — Research Paper | ScholarLens