2021PubMedRequires access

[Application of individualized controllable stress external fixation in open tibial fractures].

De-Zhong Heng, Jing Li, Jiang-Bo Zhai, Hai-Li Jia, Yichen Zhou

Open publisher page 0 citations

Abstract

OBJECTIVE: To study the clinical effect of individualized controllable stress external fixator in the treatment of open tibial fractures. METHODS: From December 2018 to July 2020, 60 patients with open tibial fractures were treated, including 35 males and 25 females;The age ranged from 23 to 58 years;The course of disease was 1.2 to 10.0 h. According to the stress stimulation on the fracture end after operation, all patients were divided into 4 groups, including non stress group (15 cases) and 3 groups with different stress stimulation(15 cases in each group). All patients with open tibial fractures were treated with controllable stress external fixator. Four weeks after operation, the stress group adjusted the elastic external fixator to apply axial stress of 1/6, 2/6 and 3/6 of their own weight to the fracture end based on the patient's weight. The wound healing of all patients after operation was observed, the plain CT images of fracture ends at 4, 6, 8, 10 and 12 weeks after operation were followed up, the average valueof callus area per 10 scanning planes was calculated, and the differences between the groups were compared. The fracture healing was observed and statistically analyzed. RESULTS: <0.05). CONCLUSION: When the controllable stress external fixation technique is used to treat open tibial fractures, the elastic external fixator is adjusted according to the patient's own weight after 4 weeks, and a certain axial stress is applied to the fracture end, which is conducive to the fracture healing of patients, and can reduce the incidence of delayed union or nonunion of open fractures, which has a certain application value.

About this research paper

What this paper is about

OBJECTIVE: To study the clinical effect of individualized controllable stress external fixator in the treatment of open tibial fractures. METHODS: From December 2018 to July 2020, 60 patients with open tibial fractures were treated, including 35 males and 25 females;The age ranged from 23 to 58 years;The course of disease was 1.2 to 10.0 h. According to the stress stimulation on the fracture end after operation, all patients were divided into 4 groups, including non stress group (15 cases) and 3 groups with different stress stimulation(15 cases in each group). All patients with open tibial fractures were treated with controllable stress external fixator. Four weeks after operation, the stress group adjusted the elastic external fixator to apply axial stress of 1/6, 2/6 and 3/6 of their own weight to the fracture end based on the patient's weight. The wound healing of all patients after operation was observed, the plain CT images of fracture ends at 4, 6, 8, 10 and 12 weeks after operation were followed up, the average valueof callus area per 10 scanning planes was calculated, and the differences between the groups were compared. The fracture healing was observed and statistically analyzed. RESULTS: <0.05). CONCLUSION: When the controllable stress external fixation technique is used to treat open tibial fractures, the elastic external fixator is adjusted according to the patient's own weight after 4 weeks, and a certain axial stress is applied to the fracture end, which is conducive to the fracture healing of patients, and can reduce the incidence of delayed union or nonunion of open fractures, which has a certain application value.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To study the clinical effect of individualized controllable stress external fixator in the treatment of open tibial fractures. METHODS: From December 2018 to July 2020, 60 patients with open tibial fractures were treated, including 35 males and 25 females;The age ranged from 23 to 58 years;The course of disease was 1.2 to 10.0 h. According to the stress stimulation on the fracture end after operation, all patients were divided into 4 groups, including non stress group (15 cases) and 3 groups with different stress stimulation(15 cases in each group). All patients with open tibial fractures were treated with controllable stress external fixator. Four weeks after operation, the stress group adjusted the elastic external fixator to apply axial stress of 1/6, 2/6 and 3/6 of their own weight to the fracture end based on the patient's weight. The wound healing of all patients after operation was observed, the plain CT images of fracture ends at 4, 6, 8, 10 and 12 weeks after operation were followed up, the average valueof callus area per 10 scanning planes was calculated, and the differences between the groups were compared. The fracture healing was observed and statistically analyzed. RESULTS: <0.05). CONCLUSION: When the controllable stress external fixation technique is used to treat open tibial fractures, the elastic external fixator is adjusted according to the patient's own weight after 4 weeks, and a certain axial stress is applied to the fracture end, which is conducive to the fracture healing of patients, and can reduce the incidence of delayed union or nonunion of open fractures, which has a certain application value.

Key concepts: Medicine, External fixation, Open fracture, Surgery, External fixator, Stress fractures, Bone healing, Tibia

Related papers

Back to paper searchBrowse research topicsOriginal source
[Application of individualized controllable stress external fixation in open tibial fractures]. — Research Paper | ScholarLens