2021•Earthquakes and StructuresRequires access

Seismic retrofit of a soft first story structure using an optimally designed post – tensioned PC frame

Assefa Jonathan Dereje, Mohamed Nour El-Din, Jinkoo Kim

Open publisher page 3 citations

Abstract

In this study, the seismic performance of a self-centering post-tensioned precast concrete (PC) frame with an enlarged beam end is evaluated for retrofit of a soft first story structure. A finite element model of a post-tensioned beam-column assembly with an enlarged beam end is validated by comparison with experimental results, and is used to validate an analytical model of the proposed system. Then the analytical model is used to retrofit a soft first story structure with only columns in the first story and infill walls above. A multi-objective optimization of the retrofit system is carried out using genetic algorithm. The seismic performance of the retrofitted structure is assessed by incremental dynamic analysis and fragility analysis. The analysis results show that the retrofit system calibrated by the optimization procedure is effective in increasing the seismic performance of the soft first story structure.

About this research paper

What this paper is about

In this study, the seismic performance of a self-centering post-tensioned precast concrete (PC) frame with an enlarged beam end is evaluated for retrofit of a soft first story structure. A finite element model of a post-tensioned beam-column assembly with an enlarged beam end is validated by comparison with experimental results, and is used to validate an analytical model of the proposed system. Then the analytical model is used to retrofit a soft first story structure with only columns in the first story and infill walls above. A multi-objective optimization of the retrofit system is carried out using genetic algorithm. The seismic performance of the retrofitted structure is assessed by incremental dynamic analysis and fragility analysis. The analysis results show that the retrofit system calibrated by the optimization procedure is effective in increasing the seismic performance of the soft first story structure.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, the seismic performance of a self-centering post-tensioned precast concrete (PC) frame with an enlarged beam end is evaluated for retrofit of a soft first story structure. A finite element model of a post-tensioned beam-column assembly with an enlarged beam end is validated by comparison with experimental results, and is used to validate an analytical model of the proposed system. Then the analytical model is used to retrofit a soft first story structure with only columns in the first story and infill walls above. A multi-objective optimization of the retrofit system is carried out using genetic algorithm. The seismic performance of the retrofitted structure is assessed by incremental dynamic analysis and fragility analysis. The analysis results show that the retrofit system calibrated by the optimization procedure is effective in increasing the seismic performance of the soft first story structure.

Key concepts: Structural engineering, Precast concrete, Infill, Frame (networking), Seismic retrofit, Fragility, Beam (structure), Finite element method

Related papers

Back to paper searchBrowse research topicsOriginal source
Seismic retrofit of a soft first story structure using an optimally designed post – tensioned PC frame — Research Paper | ScholarLens