2021IOP Conference Series Materials Science and EngineeringOpen access

Effect of damping material thickness on vibration analysis in pretension layer damping process

A Mohamed, A. Omer, Ahmed Hassan

Open full text 2 citations

Abstract

Abstract Vibration reduction is a critical necessity in many fields of engineering, technology, and industry. As a result, there is a need for vibration management. To restrict or adjust the system’s vibration response, a variety of techniques are employed. In recent years, there has been a lot of enthusiasm for the easy implementation of these vibration-control structures. The damping properties of viscoelastic materials tend to be excellent. Damping is determined by the material’s ability to dissipate energy. To minimise the vibration of vibrating surfaces, viscoelastic materials are commonly used. In this study, viscoelastic material (Dyad 606) is applied on the AL plate in the form of free layer damping and pretension layer damping. First aluminium structure using free layer damping and another one using pretension layer damping by applying tension load (two layers of damping plates, one on the top surface of the Al alloy and the other on the lower face). Passive vibration damping of the plate is achieved. These layers are influenced by axial uniform distributed load. The damping behaviour of the AL Plate is discussed in relation to the thickness variation of the pre-tension damping material. The results show that the loss factor and the attenuation percentage of the structure with pretension layer damping are increased as compared to free layer damping. It is also found that the most effective thickness of the damping material to increase the damping capacity of the framework is around half the base plate thickness

Open-access reader

About this research paper

What this paper is about

Abstract Vibration reduction is a critical necessity in many fields of engineering, technology, and industry. As a result, there is a need for vibration management. To restrict or adjust the system’s vibration response, a variety of techniques are employed. In recent years, there has been a lot of enthusiasm for the easy implementation of these vibration-control structures. The damping properties of viscoelastic materials tend to be excellent. Damping is determined by the material’s ability to dissipate energy. To minimise the vibration of vibrating surfaces, viscoelastic materials are commonly used. In this study, viscoelastic material (Dyad 606) is applied on the AL plate in the form of free layer damping and pretension layer damping. First aluminium structure using free layer damping and another one using pretension layer damping by applying tension load (two layers of damping plates, one on the top surface of the Al alloy and the other on the lower face). Passive vibration damping of the plate is achieved. These layers are influenced by axial uniform distributed load. The damping behaviour of the AL Plate is discussed in relation to the thickness variation of the pre-tension damping material. The results show that the loss factor and the attenuation percentage of the structure with pretension layer damping are increased as compared to free layer damping. It is also found that the most effective thickness of the damping material to increase the damping capacity of the framework is around half the base plate thickness

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Vibration reduction is a critical necessity in many fields of engineering, technology, and industry. As a result, there is a need for vibration management. To restrict or adjust the system’s vibration response, a variety of techniques are employed. In recent years, there has been a lot of enthusiasm for the easy implementation of these vibration-control structures. The damping properties of viscoelastic materials tend to be excellent. Damping is determined by the material’s ability to dissipate energy. To minimise the vibration of vibrating surfaces, viscoelastic materials are commonly used. In this study, viscoelastic material (Dyad 606) is applied on the AL plate in the form of free layer damping and pretension layer damping. First aluminium structure using free layer damping and another one using pretension layer damping by applying tension load (two layers of damping plates, one on the top surface of the Al alloy and the other on the lower face). Passive vibration damping of the plate is achieved. These layers are influenced by axial uniform distributed load. The damping behaviour of the AL Plate is discussed in relation to the thickness variation of the pre-tension damping material. The results show that the loss factor and the attenuation percentage of the structure with pretension layer damping are increased as compared to free layer damping. It is also found that the most effective thickness of the damping material to increase the damping capacity of the framework is around half the base plate thickness

Key concepts: Damping torque, Constrained-layer damping, Loss factor, Vibration, Materials science, Viscoelasticity, Damping capacity, Thermoelastic damping

Related papers

Back to paper searchBrowse research topicsOriginal source