2021IOP Conference Series Materials Science and EngineeringOpen access

Simulation of Effects Off Service Closed Feedwater Heater on Steam Power Plant Performance Using Cycle Tempo 5.0

Riezky Kokky Mahendra, C G Wiratama, Atok Setiyawan

Open full text 2 citations

Abstract

Abstract Steam power plant needs three important things in its operation, they are safety, reliability, and efficiency. Steam power plant efficiency can be elevated by installing regenerative feedwater heater. Feedwater heater is used to increase the temperature of water needed for combustion process in the boiler, therefore minimizing the fuel used in boiler. Case study is taken from PT. PJB UP Muara Karang Steam Power Plant unit 4 and 5. HPH 4 off service in August 2018 caused thermal efficiency drop about 1.86 % from the previous month. The same case was found in January 2019, in which HPH F off service caused 0.68 % from the previous month. This study’s aim is to find out the effect of off service closed feedwater heater to steam power plant performance using Cycle Tempo 5.0. Steam power plant unit 5 with 172 MW load is modelled on Cycle Tempo. Validation is done by comparing some parameter of simulation result to performance test result with 5% error tolerance. Few variation off service feedwater heater conditions are done by regulating valve for line bypass in order to set feedwater flow into tubes as well as drain flow. NPHR analysis is done by gathering net power and heat needed in boiler for each variation. The result obtained from this study shows that off service feedwater heater cause NPHR enhancement. The highest NPHR increase is achieved when HPH F is on off service condition, with value about 30.58 kCal/kWh. Off service HPH has bigger effect on NPHR increase than LPH on the same condition. Steam power plant efficiency increase continuously with the greater amount of operating feedwater heater. 3 LPH and 2 HPH usage on steam power plant with 172 MW load is assessed as adequate efficient, with all feedwater heater operating at 33.39 %.

Open-access reader

About this research paper

What this paper is about

Abstract Steam power plant needs three important things in its operation, they are safety, reliability, and efficiency. Steam power plant efficiency can be elevated by installing regenerative feedwater heater. Feedwater heater is used to increase the temperature of water needed for combustion process in the boiler, therefore minimizing the fuel used in boiler. Case study is taken from PT. PJB UP Muara Karang Steam Power Plant unit 4 and 5. HPH 4 off service in August 2018 caused thermal efficiency drop about 1.86 % from the previous month. The same case was found in January 2019, in which HPH F off service caused 0.68 % from the previous month. This study’s aim is to find out the effect of off service closed feedwater heater to steam power plant performance using Cycle Tempo 5.0. Steam power plant unit 5 with 172 MW load is modelled on Cycle Tempo. Validation is done by comparing some parameter of simulation result to performance test result with 5% error tolerance. Few variation off service feedwater heater conditions are done by regulating valve for line bypass in order to set feedwater flow into tubes as well as drain flow. NPHR analysis is done by gathering net power and heat needed in boiler for each variation. The result obtained from this study shows that off service feedwater heater cause NPHR enhancement. The highest NPHR increase is achieved when HPH F is on off service condition, with value about 30.58 kCal/kWh. Off service HPH has bigger effect on NPHR increase than LPH on the same condition. Steam power plant efficiency increase continuously with the greater amount of operating feedwater heater. 3 LPH and 2 HPH usage on steam power plant with 172 MW load is assessed as adequate efficient, with all feedwater heater operating at 33.39 %.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Steam power plant needs three important things in its operation, they are safety, reliability, and efficiency. Steam power plant efficiency can be elevated by installing regenerative feedwater heater. Feedwater heater is used to increase the temperature of water needed for combustion process in the boiler, therefore minimizing the fuel used in boiler. Case study is taken from PT. PJB UP Muara Karang Steam Power Plant unit 4 and 5. HPH 4 off service in August 2018 caused thermal efficiency drop about 1.86 % from the previous month. The same case was found in January 2019, in which HPH F off service caused 0.68 % from the previous month. This study’s aim is to find out the effect of off service closed feedwater heater to steam power plant performance using Cycle Tempo 5.0. Steam power plant unit 5 with 172 MW load is modelled on Cycle Tempo. Validation is done by comparing some parameter of simulation result to performance test result with 5% error tolerance. Few variation off service feedwater heater conditions are done by regulating valve for line bypass in order to set feedwater flow into tubes as well as drain flow. NPHR analysis is done by gathering net power and heat needed in boiler for each variation. The result obtained from this study shows that off service feedwater heater cause NPHR enhancement. The highest NPHR increase is achieved when HPH F is on off service condition, with value about 30.58 kCal/kWh. Off service HPH has bigger effect on NPHR increase than LPH on the same condition. Steam power plant efficiency increase continuously with the greater amount of operating feedwater heater. 3 LPH and 2 HPH usage on steam power plant with 172 MW load is assessed as adequate efficient, with all feedwater heater operating at 33.39 %.

Key concepts: Feedwater heater, Boiler feedwater, Boiler (water heating), Power station, Thermal power station, Nuclear engineering, Engineering, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Simulation of Effects Off Service Closed Feedwater Heater on Steam Power Plant Performance Using Cycle Tempo 5.0 — Research Paper | ScholarLens