2021International Conference on Mechanical Engineering, Measurement Control, and InstrumentationRequires access

Temperature field analysis of cable joint

Zengtao Hua

Open publisher page 0 citations

Abstract

In the power system, there are a large number of cable joints in the electrical transmission equipment. There are about one cable joint every 100 meters in the long-distance cable. A large number of cable joints are easy to cause internal and external faults. The fire caused by the problem of cable joints accounts for more than half of the total cable accidents. It is also a good choice to use insulation material between the cable and the environment, and to inject high insulation and good heat conduction material between the measuring point and the joint. This situation is mainly suitable for cable components with small heat capacity. For electrical equipment in normal operation, the greater the temperature difference between inside and outside the cable, the greater the resistance at the joint. It can be understood that the warning signal of cable joint failure can be replaced by the temperature of the cable.

About this research paper

What this paper is about

In the power system, there are a large number of cable joints in the electrical transmission equipment. There are about one cable joint every 100 meters in the long-distance cable. A large number of cable joints are easy to cause internal and external faults. The fire caused by the problem of cable joints accounts for more than half of the total cable accidents. It is also a good choice to use insulation material between the cable and the environment, and to inject high insulation and good heat conduction material between the measuring point and the joint. This situation is mainly suitable for cable components with small heat capacity. For electrical equipment in normal operation, the greater the temperature difference between inside and outside the cable, the greater the resistance at the joint. It can be understood that the warning signal of cable joint failure can be replaced by the temperature of the cable.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the power system, there are a large number of cable joints in the electrical transmission equipment. There are about one cable joint every 100 meters in the long-distance cable. A large number of cable joints are easy to cause internal and external faults. The fire caused by the problem of cable joints accounts for more than half of the total cable accidents. It is also a good choice to use insulation material between the cable and the environment, and to inject high insulation and good heat conduction material between the measuring point and the joint. This situation is mainly suitable for cable components with small heat capacity. For electrical equipment in normal operation, the greater the temperature difference between inside and outside the cable, the greater the resistance at the joint. It can be understood that the warning signal of cable joint failure can be replaced by the temperature of the cable.

Key concepts: Direct-buried cable, All-dielectric self-supporting cable, Power cable, Joint (building), Electrical conductor, Power transmission, Electrical engineering, Point (geometry)