New Fe2O3 Nanoparticles Modified Carbon Paste Electrode: A Cyclic Voltammetric Study Abstract
Emad Salaam Abood
Abstract
Open-access reader
Emad Salaam Abood
Abstract
Open-access reader
The cyclic voltammetry (CV) technique was accustomed to look into the electro oxidation of iron ions in water using a novel carbon paste electrode CPE enhanced with iron oxide nanoparticles. The revised electrode exhibited a high resolving function, allowing the overlapping voltametric response of Fe-ion to be resolved into a single well-defined peak. The voltage differential between Epa (anodic) and Epc (cathodic) was higher than 200 mV; this range is referred to as the quest-reversible mechanism. At temperatures ranging from 15 to 35 °C, the kinetics of the electrode were investigated. Voltammogram data revealed a rise in temperature, which resulted in an increase in negative shift, diffusion electron transfer in the Fe redox reaction. The Randles-Sevcik equation yielded a diffusion coefficient of 4.9 x 10-5; the rate constant K was 2.3 x 10-4; and the peak current of Fe-ion rose linearly with concentrations ranging from 1 to 5 ppm.
OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The cyclic voltammetry (CV) technique was accustomed to look into the electro oxidation of iron ions in water using a novel carbon paste electrode CPE enhanced with iron oxide nanoparticles. The revised electrode exhibited a high resolving function, allowing the overlapping voltametric response of Fe-ion to be resolved into a single well-defined peak. The voltage differential between Epa (anodic) and Epc (cathodic) was higher than 200 mV; this range is referred to as the quest-reversible mechanism. At temperatures ranging from 15 to 35 °C, the kinetics of the electrode were investigated. Voltammogram data revealed a rise in temperature, which resulted in an increase in negative shift, diffusion electron transfer in the Fe redox reaction. The Randles-Sevcik equation yielded a diffusion coefficient of 4.9 x 10-5; the rate constant K was 2.3 x 10-4; and the peak current of Fe-ion rose linearly with concentrations ranging from 1 to 5 ppm.
Key concepts: Electrode, Cyclic voltammetry, Redox, Diffusion, Analytical Chemistry (journal), Anode, Ion, Materials science