2021E3S Web of ConferencesOpen access

Thermodynamic Analysis of Split Air Conditioner Using Energy and Exergy Viewpoint with Low GWP Refrigerants Alternative to R410A

Punit Mishra, Shubham Soni, Govind Maheshwari

Open full text 0 citations

Abstract

In this paper, a comparative thermodynamic analysis on energy and exergy viewpoint is done on different low global warming potential (GWP) refrigerants to find the possible alternative of high GWP refrigerant R410A. R410A is used nowadays in air conditioning systems due to its ozone-friendly characteristic as zero ozone depletion potential (ODP=0) but it has high GWP (GWP=1924) that leads to global warming. Now a day’s global warming is considered to be one of the critical aspects when environmental protection is taken into consideration and researchers from every corner of the globe are working to find refrigerants that not only have zero ODP but it has low GWP too. In this analysis, four prospect refrigerants namely R32, R447A, R447B, and R452B have been studied to find their suitability to replace R410A on different performance criteria as the coefficient of performance (COP), power consumption, exergy efficiency, and exergy destruction. Thermodynamic properties of the studied refrigerants have been taken from the Genetron Properties 1.4 software. The result indicates that all the studied refrigerants have better performance characteristics compared to R410A but R447A has maximum COP and exergy efficiency along with the least total exergy destruction that makes it a possible alternate of R410A.

Open-access reader

About this research paper

What this paper is about

In this paper, a comparative thermodynamic analysis on energy and exergy viewpoint is done on different low global warming potential (GWP) refrigerants to find the possible alternative of high GWP refrigerant R410A. R410A is used nowadays in air conditioning systems due to its ozone-friendly characteristic as zero ozone depletion potential (ODP=0) but it has high GWP (GWP=1924) that leads to global warming. Now a day’s global warming is considered to be one of the critical aspects when environmental protection is taken into consideration and researchers from every corner of the globe are working to find refrigerants that not only have zero ODP but it has low GWP too. In this analysis, four prospect refrigerants namely R32, R447A, R447B, and R452B have been studied to find their suitability to replace R410A on different performance criteria as the coefficient of performance (COP), power consumption, exergy efficiency, and exergy destruction. Thermodynamic properties of the studied refrigerants have been taken from the Genetron Properties 1.4 software. The result indicates that all the studied refrigerants have better performance characteristics compared to R410A but R447A has maximum COP and exergy efficiency along with the least total exergy destruction that makes it a possible alternate of R410A.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper, a comparative thermodynamic analysis on energy and exergy viewpoint is done on different low global warming potential (GWP) refrigerants to find the possible alternative of high GWP refrigerant R410A. R410A is used nowadays in air conditioning systems due to its ozone-friendly characteristic as zero ozone depletion potential (ODP=0) but it has high GWP (GWP=1924) that leads to global warming. Now a day’s global warming is considered to be one of the critical aspects when environmental protection is taken into consideration and researchers from every corner of the globe are working to find refrigerants that not only have zero ODP but it has low GWP too. In this analysis, four prospect refrigerants namely R32, R447A, R447B, and R452B have been studied to find their suitability to replace R410A on different performance criteria as the coefficient of performance (COP), power consumption, exergy efficiency, and exergy destruction. Thermodynamic properties of the studied refrigerants have been taken from the Genetron Properties 1.4 software. The result indicates that all the studied refrigerants have better performance characteristics compared to R410A but R447A has maximum COP and exergy efficiency along with the least total exergy destruction that makes it a possible alternate of R410A.

Key concepts: Refrigerant, Exergy, Global-warming potential, Air conditioning, Ozone depletion, Coefficient of performance, Environmental science, Exergy efficiency

Related papers

Back to paper searchBrowse research topicsOriginal source
Thermodynamic Analysis of Split Air Conditioner Using Energy and Exergy Viewpoint with Low GWP Refrigerants Alternative to R410A — Research Paper | ScholarLens