2021Journal of the American Veterinary Medical AssociationRequires access

Effects of forelimb instrumentation on lameness detection in horses using a portable inertial sensor–based system

Marco A. F. Lopes, Jeremiah T. Nichols, Antônio Cézar de Oliveira Dearo, Shanna R. Nelson

Open publisher page 2 citations

Abstract

OBJECTIVE: To investigate the effects of a small sensor attached to the pastern region of a forelimb on lameness detection and quantification with a portable inertial sensor-based system (PISBS) for lameness detection and quantification in horses. ANIMALS: 20 adult horses (body weight, 410 to 650 kg) with no visible lameness at the walk. PROCEDURES: In a crossover study design, horses were evaluated at the trot twice using the PISBS with the gyroscope alternately attached to the right forelimb pastern region (as recommended by the manufacturer) or to the left forelimb pastern region (with the sensor flipped 180° on the frontal plane relative to the standard position). Agreement between the 2 instrumentation approaches was investigated graphically and by repeated-measures ANOVA, Pearson correlation analysis, and Bland-Altman analysis. RESULTS: No effects of instrumentation of a forelimb with the gyroscope were detected on the lame limb or limbs or on lameness severity. Attachment of the gyroscope to a forelimb had no effect on forelimb or hind limb lameness (ie, did not cause or mask lameness) as measured with the PISBS. CONCLUSIONS AND CLINICAL RELEVANCE: Instrumentation of a forelimb with a lightweight gyroscope for lameness evaluations with a PISBS had no effects on lameness measurements in horses. Results suggested that, when indicated, the gyroscope can be attached (while flipped 180° on the frontal plane relative to the standard position) to the left forelimb (rather than the right forelimb).

About this research paper

What this paper is about

OBJECTIVE: To investigate the effects of a small sensor attached to the pastern region of a forelimb on lameness detection and quantification with a portable inertial sensor-based system (PISBS) for lameness detection and quantification in horses. ANIMALS: 20 adult horses (body weight, 410 to 650 kg) with no visible lameness at the walk. PROCEDURES: In a crossover study design, horses were evaluated at the trot twice using the PISBS with the gyroscope alternately attached to the right forelimb pastern region (as recommended by the manufacturer) or to the left forelimb pastern region (with the sensor flipped 180° on the frontal plane relative to the standard position). Agreement between the 2 instrumentation approaches was investigated graphically and by repeated-measures ANOVA, Pearson correlation analysis, and Bland-Altman analysis. RESULTS: No effects of instrumentation of a forelimb with the gyroscope were detected on the lame limb or limbs or on lameness severity. Attachment of the gyroscope to a forelimb had no effect on forelimb or hind limb lameness (ie, did not cause or mask lameness) as measured with the PISBS. CONCLUSIONS AND CLINICAL RELEVANCE: Instrumentation of a forelimb with a lightweight gyroscope for lameness evaluations with a PISBS had no effects on lameness measurements in horses. Results suggested that, when indicated, the gyroscope can be attached (while flipped 180° on the frontal plane relative to the standard position) to the left forelimb (rather than the right forelimb).

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To investigate the effects of a small sensor attached to the pastern region of a forelimb on lameness detection and quantification with a portable inertial sensor-based system (PISBS) for lameness detection and quantification in horses. ANIMALS: 20 adult horses (body weight, 410 to 650 kg) with no visible lameness at the walk. PROCEDURES: In a crossover study design, horses were evaluated at the trot twice using the PISBS with the gyroscope alternately attached to the right forelimb pastern region (as recommended by the manufacturer) or to the left forelimb pastern region (with the sensor flipped 180° on the frontal plane relative to the standard position). Agreement between the 2 instrumentation approaches was investigated graphically and by repeated-measures ANOVA, Pearson correlation analysis, and Bland-Altman analysis. RESULTS: No effects of instrumentation of a forelimb with the gyroscope were detected on the lame limb or limbs or on lameness severity. Attachment of the gyroscope to a forelimb had no effect on forelimb or hind limb lameness (ie, did not cause or mask lameness) as measured with the PISBS. CONCLUSIONS AND CLINICAL RELEVANCE: Instrumentation of a forelimb with a lightweight gyroscope for lameness evaluations with a PISBS had no effects on lameness measurements in horses. Results suggested that, when indicated, the gyroscope can be attached (while flipped 180° on the frontal plane relative to the standard position) to the left forelimb (rather than the right forelimb).

Key concepts: Forelimb, Lameness, STRIDE, Gyroscope, Accelerometer, Medicine, Instrumentation (computer programming), Gait analysis

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of forelimb instrumentation on lameness detection in horses using a portable inertial sensor–based system — Research Paper | ScholarLens