Comparison of Compressor Performance Map Predictions to Test Data for a Supercritical Carbon Dioxide Brayton Power System
Eric M. Clementoni
Abstract
Eric M. Clementoni
Abstract
Abstract Supercritical carbon dioxide (sCO2) Brayton power cycles are typically designed to operate with compressor inlet conditions near the critical point to take advantage of the high density of the fluid at these conditions. While designing the cycle to operate here improves cycle efficiency, it also creates challenges for designing the compressor and predicting off-design compressor performance due to real gas fluid properties near the critical point. Multiple compressor performance map evaluation methodologies which incorporate real gas corrections have been proposed in literature with only limited evaluation of the accuracy of these methods compared to operational data from compressors designed for sCO2 power cycles. This paper evaluates compressor performance from the 100 kWe Integrated System Test (IST), which was operated at the Naval Nuclear Laboratory, over a range of compressor inlet conditions and rotational speeds relative to one real gas performance map correction methodology and assesses the impact of additional terms proposed in literature for improving the accuracy of off-design performance predictions.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract Supercritical carbon dioxide (sCO2) Brayton power cycles are typically designed to operate with compressor inlet conditions near the critical point to take advantage of the high density of the fluid at these conditions. While designing the cycle to operate here improves cycle efficiency, it also creates challenges for designing the compressor and predicting off-design compressor performance due to real gas fluid properties near the critical point. Multiple compressor performance map evaluation methodologies which incorporate real gas corrections have been proposed in literature with only limited evaluation of the accuracy of these methods compared to operational data from compressors designed for sCO2 power cycles. This paper evaluates compressor performance from the 100 kWe Integrated System Test (IST), which was operated at the Naval Nuclear Laboratory, over a range of compressor inlet conditions and rotational speeds relative to one real gas performance map correction methodology and assesses the impact of additional terms proposed in literature for improving the accuracy of off-design performance predictions.
Key concepts: Brayton cycle, Gas compressor, Supercritical fluid, Centrifugal compressor, Power (physics), Supercritical carbon dioxide, Computer science, Mechanical engineering