1976Defense Technical Information Center (DTIC)Requires access

Evaluation of Computer Simulated Signals or Metallic Tabs for Standardizing Eddy Current Inspection Systems.

John C. Crowe

Open publisher page 0 citations

Abstract

Nondestructive evaluation of tubing using the eddy current method normally requires standardization or calibration of the testing system against a set of known conditions or references (standards). This report presents the results of a study undertaken at Battelle-Northwest to investigate alternate means of calibration which might reduce the uncertainies experienced with the fabricated flaw method and improve the accuracy and reproducibility of eddy current inspection. Two approaches were selected for study: (1) The production of calibrating signals from specially prepared metallic-calibration tabs or passive coils translated past the eddy current inspection coil assembly. (2) The injection of electronically developed signals into the electromagnetic field surrounding the eddy current inspection probe which represent calibration or flaw responses.

About this research paper

What this paper is about

Nondestructive evaluation of tubing using the eddy current method normally requires standardization or calibration of the testing system against a set of known conditions or references (standards). This report presents the results of a study undertaken at Battelle-Northwest to investigate alternate means of calibration which might reduce the uncertainies experienced with the fabricated flaw method and improve the accuracy and reproducibility of eddy current inspection. Two approaches were selected for study: (1) The production of calibrating signals from specially prepared metallic-calibration tabs or passive coils translated past the eddy current inspection coil assembly. (2) The injection of electronically developed signals into the electromagnetic field surrounding the eddy current inspection probe which represent calibration or flaw responses.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Nondestructive evaluation of tubing using the eddy current method normally requires standardization or calibration of the testing system against a set of known conditions or references (standards). This report presents the results of a study undertaken at Battelle-Northwest to investigate alternate means of calibration which might reduce the uncertainies experienced with the fabricated flaw method and improve the accuracy and reproducibility of eddy current inspection. Two approaches were selected for study: (1) The production of calibrating signals from specially prepared metallic-calibration tabs or passive coils translated past the eddy current inspection coil assembly. (2) The injection of electronically developed signals into the electromagnetic field surrounding the eddy current inspection probe which represent calibration or flaw responses.

Key concepts: Eddy current, Calibration, Eddy-current testing, Nondestructive testing, Standardization, Electromagnetic coil, Mechanical engineering, Electromagnetic testing