2021B-ENTOpen access

Stapes angle and facial nerve-stapes head distance in patients with otosclerosis

Hüseyin Çetin, Ömer Faruk Ateş, Fazil Zeynalov, Onur Taydaş, Ayşe Şule Ateş, Ogun Taydas

Open full text 1 citations

Abstract

Objective: In this study, we aimed to compare the relationship between stapes angle, facial nerve-stapes head distance (FNSD), and densitometry in patients with otosclerosis and a control group without otosclerosis using high-resolution computed tomography (HRCT). Methods: In this retrospective study, the temporal bone CT images of patients obtained between November 2016 and January 2018 were evaluated using a dedicated workstation. The relationship between the densitometry measurements around the otic capsule, stapes angle, and FNSD were assessed and the contribution of this relationship to the diagnosis of otosclerosis was investigated. Results: The patient group was found to have lower density measured in the posterolateral to the middle turn of the cochlea than the control group (p<0.001). No statistically significant difference was found between the patient and control groups in terms of the remaining densitometry measurements. The average stapes angle was 77.72°±7.23° in the control group and 73.65°±6.38° in the patient group (p<0.001). Similarly, FNSD was found to be shorter in the patient group than in the control group (p<0.001). Conclusion: In addition to the densitometry values in HRCT, FNSD and stapes angle values can be used in the radiological diagnosis of otosclerosis. However, additional studies are needed to determine the exact reference points in stapes angle measurements.

About this research paper

What this paper is about

Objective: In this study, we aimed to compare the relationship between stapes angle, facial nerve-stapes head distance (FNSD), and densitometry in patients with otosclerosis and a control group without otosclerosis using high-resolution computed tomography (HRCT). Methods: In this retrospective study, the temporal bone CT images of patients obtained between November 2016 and January 2018 were evaluated using a dedicated workstation. The relationship between the densitometry measurements around the otic capsule, stapes angle, and FNSD were assessed and the contribution of this relationship to the diagnosis of otosclerosis was investigated. Results: The patient group was found to have lower density measured in the posterolateral to the middle turn of the cochlea than the control group (p<0.001). No statistically significant difference was found between the patient and control groups in terms of the remaining densitometry measurements. The average stapes angle was 77.72°±7.23° in the control group and 73.65°±6.38° in the patient group (p<0.001). Similarly, FNSD was found to be shorter in the patient group than in the control group (p<0.001). Conclusion: In addition to the densitometry values in HRCT, FNSD and stapes angle values can be used in the radiological diagnosis of otosclerosis. However, additional studies are needed to determine the exact reference points in stapes angle measurements.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: In this study, we aimed to compare the relationship between stapes angle, facial nerve-stapes head distance (FNSD), and densitometry in patients with otosclerosis and a control group without otosclerosis using high-resolution computed tomography (HRCT). Methods: In this retrospective study, the temporal bone CT images of patients obtained between November 2016 and January 2018 were evaluated using a dedicated workstation. The relationship between the densitometry measurements around the otic capsule, stapes angle, and FNSD were assessed and the contribution of this relationship to the diagnosis of otosclerosis was investigated. Results: The patient group was found to have lower density measured in the posterolateral to the middle turn of the cochlea than the control group (p<0.001). No statistically significant difference was found between the patient and control groups in terms of the remaining densitometry measurements. The average stapes angle was 77.72°±7.23° in the control group and 73.65°±6.38° in the patient group (p<0.001). Similarly, FNSD was found to be shorter in the patient group than in the control group (p<0.001). Conclusion: In addition to the densitometry values in HRCT, FNSD and stapes angle values can be used in the radiological diagnosis of otosclerosis. However, additional studies are needed to determine the exact reference points in stapes angle measurements.

Key concepts: Stapes, Otosclerosis, Facial nerve, Anatomy, Medicine, Orthodontics, Audiology, Middle ear

Related papers

Back to paper searchBrowse research topicsOriginal source
Stapes angle and facial nerve-stapes head distance in patients with otosclerosis — Research Paper | ScholarLens