2021Journal of Aerosol Medicine and Pulmonary Drug DeliveryRequires access

Modeling of Inhalation Profiles Through Dry Powder Inhaler in Healthy Adults and Asthma Patients As a Prerequisite for Further In Vitro and In Silico Studies

Agata Dorosz, Tomasz Urbankowski, Krzysztof Zieliński, Marcin Michnikowski, Rafał Krenke, Arkadiusz Moskal

Open publisher page 6 citations

Abstract

Background: The severity of airway obstruction may affect patient's ability to perform an effective drug inhalation from a dry powder inhaler (DPI). Also, an incorrect inhalation technique may negatively affect the efficacy of asthma treatment. The aims of the study were (1) to analyze and compare inhalation profiles recorded with the use of different inhalation techniques, and thus, (2) to establish model inhalation profiles representative for healthy subjects and subjects with mild and moderate-to-severe asthma. Methods: This study was performed in healthy volunteers, patients with mild and moderate-to-severe asthma. A modified flow-volume test to define two different expiratory levels (to residual volume and half-way to residual volume) was performed. Inspiratory flow parameters were extracted: peak inspiratory flow rate (PIFinh), time at which peak inspiratory flow rate occurs (tPIFinh), total inhalation time (T), and inhaled volume (V). Test of frequency for tPIFinh100% and tPIFinh50% by asthma severity was performed, to provide information about initial flow accelerations. The impact of two different expiratory levels preceding inhalation (with severity of asthma as a categorical factor) on inspiratory flow parameters was examined. Results: PIFinh was dependent upon asthma severity (p = 0.046). Type of exhalation before inhalation had no effect on PIFinh values. V value was significantly affected both by asthma severity (p = 0.024) and type of exhalation before inhalation (p < 0.0001). Mean T value was influenced by type of exhalation before inhalation (p = 0.0003), but not by asthma severity. Mean tPIFinh value was affected by the type of exhalation before inhalation only in healthy subjects (p = 0.01). Conclusions: Both asthma severity and type of exhalation before inhalation have little impact on the dynamics of inhalation through a DPI. An alternative form of equation describing inhalation profiles demonstrating a relationship between lung mechanics and dynamics of inspiratory profile has been proposed.

About this research paper

What this paper is about

Background: The severity of airway obstruction may affect patient's ability to perform an effective drug inhalation from a dry powder inhaler (DPI). Also, an incorrect inhalation technique may negatively affect the efficacy of asthma treatment. The aims of the study were (1) to analyze and compare inhalation profiles recorded with the use of different inhalation techniques, and thus, (2) to establish model inhalation profiles representative for healthy subjects and subjects with mild and moderate-to-severe asthma. Methods: This study was performed in healthy volunteers, patients with mild and moderate-to-severe asthma. A modified flow-volume test to define two different expiratory levels (to residual volume and half-way to residual volume) was performed. Inspiratory flow parameters were extracted: peak inspiratory flow rate (PIFinh), time at which peak inspiratory flow rate occurs (tPIFinh), total inhalation time (T), and inhaled volume (V). Test of frequency for tPIFinh100% and tPIFinh50% by asthma severity was performed, to provide information about initial flow accelerations. The impact of two different expiratory levels preceding inhalation (with severity of asthma as a categorical factor) on inspiratory flow parameters was examined. Results: PIFinh was dependent upon asthma severity (p = 0.046). Type of exhalation before inhalation had no effect on PIFinh values. V value was significantly affected both by asthma severity (p = 0.024) and type of exhalation before inhalation (p < 0.0001). Mean T value was influenced by type of exhalation before inhalation (p = 0.0003), but not by asthma severity. Mean tPIFinh value was affected by the type of exhalation before inhalation only in healthy subjects (p = 0.01). Conclusions: Both asthma severity and type of exhalation before inhalation have little impact on the dynamics of inhalation through a DPI. An alternative form of equation describing inhalation profiles demonstrating a relationship between lung mechanics and dynamics of inspiratory profile has been proposed.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: The severity of airway obstruction may affect patient's ability to perform an effective drug inhalation from a dry powder inhaler (DPI). Also, an incorrect inhalation technique may negatively affect the efficacy of asthma treatment. The aims of the study were (1) to analyze and compare inhalation profiles recorded with the use of different inhalation techniques, and thus, (2) to establish model inhalation profiles representative for healthy subjects and subjects with mild and moderate-to-severe asthma. Methods: This study was performed in healthy volunteers, patients with mild and moderate-to-severe asthma. A modified flow-volume test to define two different expiratory levels (to residual volume and half-way to residual volume) was performed. Inspiratory flow parameters were extracted: peak inspiratory flow rate (PIFinh), time at which peak inspiratory flow rate occurs (tPIFinh), total inhalation time (T), and inhaled volume (V). Test of frequency for tPIFinh100% and tPIFinh50% by asthma severity was performed, to provide information about initial flow accelerations. The impact of two different expiratory levels preceding inhalation (with severity of asthma as a categorical factor) on inspiratory flow parameters was examined. Results: PIFinh was dependent upon asthma severity (p = 0.046). Type of exhalation before inhalation had no effect on PIFinh values. V value was significantly affected both by asthma severity (p = 0.024) and type of exhalation before inhalation (p < 0.0001). Mean T value was influenced by type of exhalation before inhalation (p = 0.0003), but not by asthma severity. Mean tPIFinh value was affected by the type of exhalation before inhalation only in healthy subjects (p = 0.01). Conclusions: Both asthma severity and type of exhalation before inhalation have little impact on the dynamics of inhalation through a DPI. An alternative form of equation describing inhalation profiles demonstrating a relationship between lung mechanics and dynamics of inspiratory profile has been proposed.

Key concepts: Inhalation, Exhalation, Dry-powder inhaler, Asthma, Medicine, Inhaler, Expiration, Anesthesia

Related papers

Back to paper searchBrowse research topicsOriginal source
Modeling of Inhalation Profiles Through Dry Powder Inhaler in Healthy Adults and Asthma Patients As a Prerequisite for Further In Vitro and In Silico Studies — Research Paper | ScholarLens