A simple and sensitive aptasensor with rolling circle amplification for viable Cronobacter sakazakii detection in powdered infant formula
Ju Liu, Guoyang Xie, Qin Xiong, Dan Mu, Hengyi Xu
Abstract
Open-access reader
Ju Liu, Guoyang Xie, Qin Xiong, Dan Mu, Hengyi Xu
Abstract
Open-access reader
Cronobacter sakazakii is a foodborne, emerging opportunistic pathogen that causes severe bacteremia, necrotizing enterocolitis, and sepsis with a mortality rate of up to 80%. In this study, we developed a simple and sensitive fluorescent turn-off aptasensor with rolling circle amplification assay for viable C. sakazakii detection in powdered infant formula. The results showed that the proposed aptasensor has good performance and specificity for detecting viable C. sakazakii in pure culture and powdered infant formula samples within 3 h. Under the optimal reaction conditions, there is a linear relationship between fluorescent intensity at 490 nm and logarithmic concentration of C. sakazakii in the range of 2.7 × 10 5 to 2.7 × 10 2 cfu/mL, with a limit of detection of 2.7 × 10 2 cfu/mL in pure culture. The proposed aptasensor achieved a recovery of 104 to 111% in pure culture, and 96 to 107% in spiked powdered infant formula samples. The proposed aptasensor does not require complicated DNA extraction steps or antibodies, and can be performed at 37°C, making it a convenient and sensitive strategy for C. sakazakii detection.
OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Cronobacter sakazakii is a foodborne, emerging opportunistic pathogen that causes severe bacteremia, necrotizing enterocolitis, and sepsis with a mortality rate of up to 80%. In this study, we developed a simple and sensitive fluorescent turn-off aptasensor with rolling circle amplification assay for viable C. sakazakii detection in powdered infant formula. The results showed that the proposed aptasensor has good performance and specificity for detecting viable C. sakazakii in pure culture and powdered infant formula samples within 3 h. Under the optimal reaction conditions, there is a linear relationship between fluorescent intensity at 490 nm and logarithmic concentration of C. sakazakii in the range of 2.7 × 10 5 to 2.7 × 10 2 cfu/mL, with a limit of detection of 2.7 × 10 2 cfu/mL in pure culture. The proposed aptasensor achieved a recovery of 104 to 111% in pure culture, and 96 to 107% in spiked powdered infant formula samples. The proposed aptasensor does not require complicated DNA extraction steps or antibodies, and can be performed at 37°C, making it a convenient and sensitive strategy for C. sakazakii detection.
Key concepts: Cronobacter sakazakii, Infant formula, Detection limit, Microbiology, Necrotizing enterocolitis, Chromatography, Chemistry, Biology