2021Asian Journal of Chemical SciencesOpen access

Exploring the Additive Effects of Aluminium and Potassium Sulfates in Enhancing the Charge Cycle of Lead Acid Batteries

Chijioke Elijah Onu, Nnabundo Musei, Philomena Kanwulia Igbokwe

Open full text 1 citations

Abstract

The adoption of aluminium sulfate and potassium sulfate as electrolyte additives were investigated to determine the possibility of enhancing the charge cycle of 2V/ 20AH lead acid battery with reference to the conventional dilute sulfuric acid electrolyte. The duration and efficiency of lead acid batteries have been a challenge for industries over time due to weak electrolyte and insufficient charge cycle leading to sulfation. This has affected the long-term production output in manufacturing companies that depend on lead acid batteries as alternative power source. Hence there is need to explore the use of specific sulfate additives that can possibly address this gap. The electrolyte solutions were in three separate charge and discharge cycles involving dilute sulfuric acid electrolyte, dilute sulfuric acid-aluminium sulfate mixed electrolyte and dilute sulfuric acid-potassium sulfate mixed electrolyte for one hour each. The total voltage after 30 minutes charge cycle was 2.3V, 2.35V and 5.10V for dilute sulfuric acid, aluminium sulfate additive and potassium sulfate additive respectively. The cell efficiency for dilute sulfuric acid, aluminium sulfate additive and potassium sulfate additive electrolytes are 77%, 77% and 33% respectively. The electrolyte sulfate additives were of no positive impact to the conventional dilute sulfuric acid electrolyte of a typical lead acid battery due to the low difference in potentials between the terminals.

About this research paper

What this paper is about

The adoption of aluminium sulfate and potassium sulfate as electrolyte additives were investigated to determine the possibility of enhancing the charge cycle of 2V/ 20AH lead acid battery with reference to the conventional dilute sulfuric acid electrolyte. The duration and efficiency of lead acid batteries have been a challenge for industries over time due to weak electrolyte and insufficient charge cycle leading to sulfation. This has affected the long-term production output in manufacturing companies that depend on lead acid batteries as alternative power source. Hence there is need to explore the use of specific sulfate additives that can possibly address this gap. The electrolyte solutions were in three separate charge and discharge cycles involving dilute sulfuric acid electrolyte, dilute sulfuric acid-aluminium sulfate mixed electrolyte and dilute sulfuric acid-potassium sulfate mixed electrolyte for one hour each. The total voltage after 30 minutes charge cycle was 2.3V, 2.35V and 5.10V for dilute sulfuric acid, aluminium sulfate additive and potassium sulfate additive respectively. The cell efficiency for dilute sulfuric acid, aluminium sulfate additive and potassium sulfate additive electrolytes are 77%, 77% and 33% respectively. The electrolyte sulfate additives were of no positive impact to the conventional dilute sulfuric acid electrolyte of a typical lead acid battery due to the low difference in potentials between the terminals.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The adoption of aluminium sulfate and potassium sulfate as electrolyte additives were investigated to determine the possibility of enhancing the charge cycle of 2V/ 20AH lead acid battery with reference to the conventional dilute sulfuric acid electrolyte. The duration and efficiency of lead acid batteries have been a challenge for industries over time due to weak electrolyte and insufficient charge cycle leading to sulfation. This has affected the long-term production output in manufacturing companies that depend on lead acid batteries as alternative power source. Hence there is need to explore the use of specific sulfate additives that can possibly address this gap. The electrolyte solutions were in three separate charge and discharge cycles involving dilute sulfuric acid electrolyte, dilute sulfuric acid-aluminium sulfate mixed electrolyte and dilute sulfuric acid-potassium sulfate mixed electrolyte for one hour each. The total voltage after 30 minutes charge cycle was 2.3V, 2.35V and 5.10V for dilute sulfuric acid, aluminium sulfate additive and potassium sulfate additive respectively. The cell efficiency for dilute sulfuric acid, aluminium sulfate additive and potassium sulfate additive electrolytes are 77%, 77% and 33% respectively. The electrolyte sulfate additives were of no positive impact to the conventional dilute sulfuric acid electrolyte of a typical lead acid battery due to the low difference in potentials between the terminals.

Key concepts: Sulfuric acid, Electrolyte, Inorganic chemistry, Sulfate, Chemistry, Potassium, Potassium sulfate, Aluminium

Related papers

Back to paper searchBrowse research topicsOriginal source
Exploring the Additive Effects of Aluminium and Potassium Sulfates in Enhancing the Charge Cycle of Lead Acid Batteries — Research Paper | ScholarLens