Calibration and initial validation of a low-cost computer-based screening audiometer coupled to consumer insert phone-earmuff combination for boothless audiometry
Kumar Seluakumaran, Majdina N. Shaharudin
Abstract
Kumar Seluakumaran, Majdina N. Shaharudin
Abstract
OBJECTIVE: To undertake calibration and preliminary validation of a custom-designed computer-based screening audiometer connected to consumer insert phone-earmuff combination for adult pure tone audiometry. DESIGN: Part 1 involved electroacoustic measurement and biological calibration of a laptop-earphone pair used for the computer-based audiometry (CBA). Part 2 compared CBA thresholds obtained without a sound booth with those measured using the gold-standard clinical audiometry. STUDY SAMPLE: 17 young normal-hearing volunteers (Part 1) and 43 normal and hearing loss subjects (Part 2) recruited from an audiology clinic via convenience sampling. RESULTS: < 0.0001) and had a good degree of agreement (mean difference of -1.06 ± 7.63 dB). Also, the CBA showed about 90% sensitivity and 80% specificity for detecting hearing loss based on low (0.5, 1, 2 kHz) and high frequency (4, 8 kHz) pure tone averages of >25 dB HL. CONCLUSIONS: The use of a computer-based audiometer application with consumer insert phone-earmuff combination can offer a cost-effective solution for boothless screening audiometry.
OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To undertake calibration and preliminary validation of a custom-designed computer-based screening audiometer connected to consumer insert phone-earmuff combination for adult pure tone audiometry. DESIGN: Part 1 involved electroacoustic measurement and biological calibration of a laptop-earphone pair used for the computer-based audiometry (CBA). Part 2 compared CBA thresholds obtained without a sound booth with those measured using the gold-standard clinical audiometry. STUDY SAMPLE: 17 young normal-hearing volunteers (Part 1) and 43 normal and hearing loss subjects (Part 2) recruited from an audiology clinic via convenience sampling. RESULTS: < 0.0001) and had a good degree of agreement (mean difference of -1.06 ± 7.63 dB). Also, the CBA showed about 90% sensitivity and 80% specificity for detecting hearing loss based on low (0.5, 1, 2 kHz) and high frequency (4, 8 kHz) pure tone averages of >25 dB HL. CONCLUSIONS: The use of a computer-based audiometer application with consumer insert phone-earmuff combination can offer a cost-effective solution for boothless screening audiometry.
Key concepts: Audiometer, Audiometry, Audiology, Calibration, Pure tone audiometry, Hearing loss, Medicine, Phone