2020•Power ResearchOpen access

Conformance Testing for IEC 61850 Communication Protocol of Intelligent Electronic Devices

M. Pradish, Amit Jain

Open full text 2 citations

Abstract

There are various Intelligent Electronic Devices (IEDs) placed in a Substation Automation System (SAS) based substations. These IEDs are meant for performing the respective functionalities that they are intended for, which includes protective relays, transformer tap changers, Bay control units, RTUs, Protocol Converters etc., present in a substation. These IEDs are also required to communicate with each other and that may include IEDs from various other manufactures also. This paper provides brief details of the IEC 61850 standards and the test procedures formulated by UCA International Users Group (UCA IuG) used for testing Server IEDs which are used to validate for their conformance to the standard. This paper also helps in addressing the interoperability of IEC 61850 based IEDs among the multivendor solutions subjected to conformance testing and are used in the Substations.

About this research paper

What this paper is about

There are various Intelligent Electronic Devices (IEDs) placed in a Substation Automation System (SAS) based substations. These IEDs are meant for performing the respective functionalities that they are intended for, which includes protective relays, transformer tap changers, Bay control units, RTUs, Protocol Converters etc., present in a substation. These IEDs are also required to communicate with each other and that may include IEDs from various other manufactures also. This paper provides brief details of the IEC 61850 standards and the test procedures formulated by UCA International Users Group (UCA IuG) used for testing Server IEDs which are used to validate for their conformance to the standard. This paper also helps in addressing the interoperability of IEC 61850 based IEDs among the multivendor solutions subjected to conformance testing and are used in the Substations.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

There are various Intelligent Electronic Devices (IEDs) placed in a Substation Automation System (SAS) based substations. These IEDs are meant for performing the respective functionalities that they are intended for, which includes protective relays, transformer tap changers, Bay control units, RTUs, Protocol Converters etc., present in a substation. These IEDs are also required to communicate with each other and that may include IEDs from various other manufactures also. This paper provides brief details of the IEC 61850 standards and the test procedures formulated by UCA International Users Group (UCA IuG) used for testing Server IEDs which are used to validate for their conformance to the standard. This paper also helps in addressing the interoperability of IEC 61850 based IEDs among the multivendor solutions subjected to conformance testing and are used in the Substations.

Key concepts: IEC 61850, Interoperability, International standard, Automation, Conformance testing, Protocol (science), Embedded system, Computer science

Related papers

Back to paper searchBrowse research topicsOriginal source
Conformance Testing for IEC 61850 Communication Protocol of Intelligent Electronic Devices — Research Paper | ScholarLens