Analysis Of The Effect Of Alternator Modification On Himoinsa Genset 20 Kva To Load Testing And Cost
Iwan Hadi Suratno, A’rasy Fahruddin
Abstract
Open-access reader
Iwan Hadi Suratno, A’rasy Fahruddin
Abstract
Open-access reader
A generator is a device or engine that generates electrical energy from the presence of mechanical energy obtained from a prime mover in the form of a diesel engine as the prime mover which then drives an AC generator or alternator, causing an electrical voltage. The aim of this research is that the generator can supply electricity needs at the Sumur Welut site by changing or modifying diameter of the wire on the alternator. This analysis includes the Stator and Rotor on the Alternator generator so that it can produce the electricity needed. From the test results, the load generated after being modified can supply power at the site but the fuel consumption is more wasteful, namely 0.9 liters / minute and also the generator temperature increases to 88.2 C. So that the radiator planning is done by changing the surface area of the radiator from 2915 cm2 to 8077 cm2. Or change the radiator fan, which originally changed the wind speed of 4.7 m / s to 13 m / s. Keywords: Generator, Alternator, Load Testing, Radiator, Cost.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A generator is a device or engine that generates electrical energy from the presence of mechanical energy obtained from a prime mover in the form of a diesel engine as the prime mover which then drives an AC generator or alternator, causing an electrical voltage. The aim of this research is that the generator can supply electricity needs at the Sumur Welut site by changing or modifying diameter of the wire on the alternator. This analysis includes the Stator and Rotor on the Alternator generator so that it can produce the electricity needed. From the test results, the load generated after being modified can supply power at the site but the fuel consumption is more wasteful, namely 0.9 liters / minute and also the generator temperature increases to 88.2 C. So that the radiator planning is done by changing the surface area of the radiator from 2915 cm2 to 8077 cm2. Or change the radiator fan, which originally changed the wind speed of 4.7 m / s to 13 m / s. Keywords: Generator, Alternator, Load Testing, Radiator, Cost.
Key concepts: Alternator, Prime mover, Radiator (engine cooling), Automotive engineering, Stator, Rotor (electric), Electric generator, Generator (circuit theory)