2021Journal of Thoracic DiseaseOpen access

Efficacy and safety of a new disposable percutaneous positioning device invented to facilitate the precision of percutaneous core needle lung biopsies: a prospective, open and randomized controlled study

Yunhua Xu, Jun Fu, Wenwei Cao, Li Zhu, Yuehui Jin, Qing Yin, Jianding Ye, Haiyan Zhou

Open full text 5 citations

Abstract

Background: A new disposable percutaneous positioning device was developed which permits adjustment of the fixing puncture angle while performing a percutaneous core needle lung biopsy (CNLB). The aim of the study was to explore the positioning accuracy and clinical safety of the new device during CT-guided percutaneous CNLB. Methods: A prospective, open and randomized controlled study with two parallel groups was conducted on 150 patients with pulmonary nodules between July 1, 2018 and June 30, 2019 including 101 males and 49 females who were divided (allocation ratio: 1:1) into a standard CNLB group without the percutaneous positioning device (control, n=75) and a new percutaneous positioning device group combined with CNLB (experimental, n=75). The efficacy was determined by the success rate of reaching the target location on the first percutaneous attempt, the number of CT scans performed and the time required for successful puncture positioning. Safety evaluations included complications related to percutaneous surgery and the new positioning device. Results: The success rate of reaching the target location on the first percutaneous attempt in the experimental group was significantly higher than in the control group [96.0% (72/75) vs. 42.7% (32/75), P<0.001]. Patients in the experimental group received 3.05±0.28 times CT scans on average for successful percutaneous positioning, which was significantly lower than for the control group (3.95±1.03) (P<0.001). The time required to complete the percutaneous positioning was significantly lower in the experimental group compared to the control group (8.73±3.11 vs. 12.79±4.55 min, P<0.001). There was no significant difference in percutaneous-related complications between the two groups [48.0% (36/75) vs. 61.3% (46/75), P=0.101], except that the bleeding rate in the experimental group was lower than in the control group [26.7% (20/75) vs. 46.7% (35/75), P=0.032]. Conclusions: The use of the optimized percutaneous technology with the new positioning device significantly improved the accuracy and precision of percutaneous lung biopsies. Trial Registration: ChiCTR-INR-17010322.

Open-access reader

About this research paper

What this paper is about

Background: A new disposable percutaneous positioning device was developed which permits adjustment of the fixing puncture angle while performing a percutaneous core needle lung biopsy (CNLB). The aim of the study was to explore the positioning accuracy and clinical safety of the new device during CT-guided percutaneous CNLB. Methods: A prospective, open and randomized controlled study with two parallel groups was conducted on 150 patients with pulmonary nodules between July 1, 2018 and June 30, 2019 including 101 males and 49 females who were divided (allocation ratio: 1:1) into a standard CNLB group without the percutaneous positioning device (control, n=75) and a new percutaneous positioning device group combined with CNLB (experimental, n=75). The efficacy was determined by the success rate of reaching the target location on the first percutaneous attempt, the number of CT scans performed and the time required for successful puncture positioning. Safety evaluations included complications related to percutaneous surgery and the new positioning device. Results: The success rate of reaching the target location on the first percutaneous attempt in the experimental group was significantly higher than in the control group [96.0% (72/75) vs. 42.7% (32/75), P<0.001]. Patients in the experimental group received 3.05±0.28 times CT scans on average for successful percutaneous positioning, which was significantly lower than for the control group (3.95±1.03) (P<0.001). The time required to complete the percutaneous positioning was significantly lower in the experimental group compared to the control group (8.73±3.11 vs. 12.79±4.55 min, P<0.001). There was no significant difference in percutaneous-related complications between the two groups [48.0% (36/75) vs. 61.3% (46/75), P=0.101], except that the bleeding rate in the experimental group was lower than in the control group [26.7% (20/75) vs. 46.7% (35/75), P=0.032]. Conclusions: The use of the optimized percutaneous technology with the new positioning device significantly improved the accuracy and precision of percutaneous lung biopsies. Trial Registration: ChiCTR-INR-17010322.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background: A new disposable percutaneous positioning device was developed which permits adjustment of the fixing puncture angle while performing a percutaneous core needle lung biopsy (CNLB). The aim of the study was to explore the positioning accuracy and clinical safety of the new device during CT-guided percutaneous CNLB. Methods: A prospective, open and randomized controlled study with two parallel groups was conducted on 150 patients with pulmonary nodules between July 1, 2018 and June 30, 2019 including 101 males and 49 females who were divided (allocation ratio: 1:1) into a standard CNLB group without the percutaneous positioning device (control, n=75) and a new percutaneous positioning device group combined with CNLB (experimental, n=75). The efficacy was determined by the success rate of reaching the target location on the first percutaneous attempt, the number of CT scans performed and the time required for successful puncture positioning. Safety evaluations included complications related to percutaneous surgery and the new positioning device. Results: The success rate of reaching the target location on the first percutaneous attempt in the experimental group was significantly higher than in the control group [96.0% (72/75) vs. 42.7% (32/75), P<0.001]. Patients in the experimental group received 3.05±0.28 times CT scans on average for successful percutaneous positioning, which was significantly lower than for the control group (3.95±1.03) (P<0.001). The time required to complete the percutaneous positioning was significantly lower in the experimental group compared to the control group (8.73±3.11 vs. 12.79±4.55 min, P<0.001). There was no significant difference in percutaneous-related complications between the two groups [48.0% (36/75) vs. 61.3% (46/75), P=0.101], except that the bleeding rate in the experimental group was lower than in the control group [26.7% (20/75) vs. 46.7% (35/75), P=0.032]. Conclusions: The use of the optimized percutaneous technology with the new positioning device significantly improved the accuracy and precision of percutaneous lung biopsies. Trial Registration: ChiCTR-INR-17010322.

Key concepts: Percutaneous, Medicine, Surgery, Radiology, Randomized controlled trial, Prospective cohort study

Related papers

Back to paper searchBrowse research topicsOriginal source
Efficacy and safety of a new disposable percutaneous positioning device invented to facilitate the precision of percutaneous core needle lung biopsies: a prospective, open and randomized controlled study — Research Paper | ScholarLens