2022Monthly Notices of the Royal Astronomical SocietyOpen access

Different molecular filament widths as tracers of accretion on to filaments

Gilberto C. Gómez, Catherine Walsh, Aina Palau

Open full text 5 citations

Abstract

ABSTRACT We explore how dense filament widths, when measured using different molecular species, may change as a consequence of gas accretion towards the filament. As a gas parcel falls into the filament, it will experience different density, temperature, and extinction values. The rate at which this environment changes will affect differently the abundance of different molecules. So, a molecule that forms quickly will better reflect the local physical conditions a gas parcel experiences than a slower forming molecule. Since these differences depend on how the respective time-scales compare, the different molecular distributions should reflect how rapidly the environment changes, i.e. the accretion rate towards the filament. We find that the filament widths measured from time-dependent abundances for C2H, CO, CN, CS, and C3H2 are the most sensitive to this effect. This is because these molecules are the ones presenting also the wider filament widths. On the contrary, molecules such as N2H+, NH3, H2CO, HNC, and CH3OH are not so sensitive to accretion and present the narrowest filament widths. We propose that ratios of filament widths for different tracers could be a useful tool to estimate the accretion rate on to the filament.

Open-access reader

About this research paper

What this paper is about

ABSTRACT We explore how dense filament widths, when measured using different molecular species, may change as a consequence of gas accretion towards the filament. As a gas parcel falls into the filament, it will experience different density, temperature, and extinction values. The rate at which this environment changes will affect differently the abundance of different molecules. So, a molecule that forms quickly will better reflect the local physical conditions a gas parcel experiences than a slower forming molecule. Since these differences depend on how the respective time-scales compare, the different molecular distributions should reflect how rapidly the environment changes, i.e. the accretion rate towards the filament. We find that the filament widths measured from time-dependent abundances for C2H, CO, CN, CS, and C3H2 are the most sensitive to this effect. This is because these molecules are the ones presenting also the wider filament widths. On the contrary, molecules such as N2H+, NH3, H2CO, HNC, and CH3OH are not so sensitive to accretion and present the narrowest filament widths. We propose that ratios of filament widths for different tracers could be a useful tool to estimate the accretion rate on to the filament.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

ABSTRACT We explore how dense filament widths, when measured using different molecular species, may change as a consequence of gas accretion towards the filament. As a gas parcel falls into the filament, it will experience different density, temperature, and extinction values. The rate at which this environment changes will affect differently the abundance of different molecules. So, a molecule that forms quickly will better reflect the local physical conditions a gas parcel experiences than a slower forming molecule. Since these differences depend on how the respective time-scales compare, the different molecular distributions should reflect how rapidly the environment changes, i.e. the accretion rate towards the filament. We find that the filament widths measured from time-dependent abundances for C2H, CO, CN, CS, and C3H2 are the most sensitive to this effect. This is because these molecules are the ones presenting also the wider filament widths. On the contrary, molecules such as N2H+, NH3, H2CO, HNC, and CH3OH are not so sensitive to accretion and present the narrowest filament widths. We propose that ratios of filament widths for different tracers could be a useful tool to estimate the accretion rate on to the filament.

Key concepts: Protein filament, Accretion (finance), Physics, Astrophysics, Molecule, Chemical physics, Atomic physics, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Different molecular filament widths as tracers of accretion on to filaments — Research Paper | ScholarLens