2021Canadian Journal of Civil EngineeringRequires access

Regulation response of pilot-operated diaphragm type pressure-reducing valves: laboratory testing and impact on the performance of pressure control modes in water distribution systems

Mouna Doghri, Sophie Duchesne, Annie Poulin, J. P. Villeneuve

Open publisher page 3 citations

Abstract

Pressure control is recognized as an efficient measure for reducing leaks from water distribution systems. We have evaluated the effectiveness of various pressure control modes by means of pilot-operated diaphragm type pressure-reducing valves (PRVs), taking into account the sensitivity of the valves to various settings. First, the response of a PRV to consecutive pressure settings variations was experimentally evaluated in the hydraulic simulation laboratory of National Institute for Scientific Research. These experiments revealed that the studied valve only reacts when variation in the pressure setting corresponds to at least a 1/6 turn of the pilot valve. Second, an actual case study from Quebec City, Canada, was simulated to evaluate the impact of the PRV response on three pressure control modes: fixed control, time-based control, and real-time control (RTC). The results show that RTC of pressure leads to reductions in leakage rate for the studied network but that the PRV operational constraints limit the expected performance of RTC.

About this research paper

What this paper is about

Pressure control is recognized as an efficient measure for reducing leaks from water distribution systems. We have evaluated the effectiveness of various pressure control modes by means of pilot-operated diaphragm type pressure-reducing valves (PRVs), taking into account the sensitivity of the valves to various settings. First, the response of a PRV to consecutive pressure settings variations was experimentally evaluated in the hydraulic simulation laboratory of National Institute for Scientific Research. These experiments revealed that the studied valve only reacts when variation in the pressure setting corresponds to at least a 1/6 turn of the pilot valve. Second, an actual case study from Quebec City, Canada, was simulated to evaluate the impact of the PRV response on three pressure control modes: fixed control, time-based control, and real-time control (RTC). The results show that RTC of pressure leads to reductions in leakage rate for the studied network but that the PRV operational constraints limit the expected performance of RTC.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Pressure control is recognized as an efficient measure for reducing leaks from water distribution systems. We have evaluated the effectiveness of various pressure control modes by means of pilot-operated diaphragm type pressure-reducing valves (PRVs), taking into account the sensitivity of the valves to various settings. First, the response of a PRV to consecutive pressure settings variations was experimentally evaluated in the hydraulic simulation laboratory of National Institute for Scientific Research. These experiments revealed that the studied valve only reacts when variation in the pressure setting corresponds to at least a 1/6 turn of the pilot valve. Second, an actual case study from Quebec City, Canada, was simulated to evaluate the impact of the PRV response on three pressure control modes: fixed control, time-based control, and real-time control (RTC). The results show that RTC of pressure leads to reductions in leakage rate for the studied network but that the PRV operational constraints limit the expected performance of RTC.

Key concepts: Pressure regulator, Control valves, Pressure control, Relief valve, Leakage (economics), Diaphragm (acoustics), Pressure sensor, Limit (mathematics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Regulation response of pilot-operated diaphragm type pressure-reducing valves: laboratory testing and impact on the performance of pressure control modes in water distribution systems — Research Paper | ScholarLens