2021Medical PhysicsOpen access

Managing occupational doses with smartphones in interventional radiology

Roberto Sánchez, Daniel Fernández, E. Vañó, J. Fernández

Open full text 12 citations

Abstract

Abstract Purpose This study presents a prototype smartphone application for occupational dosimetry in interventional practices based on electronic personal dosimeters to assist in dose monitoring. Methods The prototype receives and records information from the occupational dose report containing the cumulative dose of electronic personal dosimeters worn over the apron at chest level and electronic area dosimeters located on C‐arms (reference dosimeters), for each fluoroscopy‐guided procedure. Using their smartphones, personnel involved in interventional practices can review and compare their occupational records with an investigation level, the dose limits, and their department colleagues (anonymously). The ratio between Hp(10) measured by the personal and the reference dosimeters at the C‐arm is presented as an indicator of consistent use of suspended operator shield. Some general results extracted from the first months of use are presented. Results The reference dosimeter located at the C‐arm (without lead protection and acting as an ambient dosimeter) recorded in one of the laboratories 217 mSv during 308 procedures over 5 months, showing an indication of the radiation risk present in an interventional laboratory. The ratio between the personal cumulative dose and the dose at a reference C‐arm dosimeter ranged from 0.2% to 1.67% (a factor of 8.5) for different interventionalists. These differences suggest different protection habits among interventional operators, as well as a target for dose reduction. Conclusions With this system, professionals have easy access to their occupational dosimetry records (including information on the workload) in the setting of their interventional departments, to thereby actively engage in the protection process.

Open-access reader

About this research paper

What this paper is about

Abstract Purpose This study presents a prototype smartphone application for occupational dosimetry in interventional practices based on electronic personal dosimeters to assist in dose monitoring. Methods The prototype receives and records information from the occupational dose report containing the cumulative dose of electronic personal dosimeters worn over the apron at chest level and electronic area dosimeters located on C‐arms (reference dosimeters), for each fluoroscopy‐guided procedure. Using their smartphones, personnel involved in interventional practices can review and compare their occupational records with an investigation level, the dose limits, and their department colleagues (anonymously). The ratio between Hp(10) measured by the personal and the reference dosimeters at the C‐arm is presented as an indicator of consistent use of suspended operator shield. Some general results extracted from the first months of use are presented. Results The reference dosimeter located at the C‐arm (without lead protection and acting as an ambient dosimeter) recorded in one of the laboratories 217 mSv during 308 procedures over 5 months, showing an indication of the radiation risk present in an interventional laboratory. The ratio between the personal cumulative dose and the dose at a reference C‐arm dosimeter ranged from 0.2% to 1.67% (a factor of 8.5) for different interventionalists. These differences suggest different protection habits among interventional operators, as well as a target for dose reduction. Conclusions With this system, professionals have easy access to their occupational dosimetry records (including information on the workload) in the setting of their interventional departments, to thereby actively engage in the protection process.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Purpose This study presents a prototype smartphone application for occupational dosimetry in interventional practices based on electronic personal dosimeters to assist in dose monitoring. Methods The prototype receives and records information from the occupational dose report containing the cumulative dose of electronic personal dosimeters worn over the apron at chest level and electronic area dosimeters located on C‐arms (reference dosimeters), for each fluoroscopy‐guided procedure. Using their smartphones, personnel involved in interventional practices can review and compare their occupational records with an investigation level, the dose limits, and their department colleagues (anonymously). The ratio between Hp(10) measured by the personal and the reference dosimeters at the C‐arm is presented as an indicator of consistent use of suspended operator shield. Some general results extracted from the first months of use are presented. Results The reference dosimeter located at the C‐arm (without lead protection and acting as an ambient dosimeter) recorded in one of the laboratories 217 mSv during 308 procedures over 5 months, showing an indication of the radiation risk present in an interventional laboratory. The ratio between the personal cumulative dose and the dose at a reference C‐arm dosimeter ranged from 0.2% to 1.67% (a factor of 8.5) for different interventionalists. These differences suggest different protection habits among interventional operators, as well as a target for dose reduction. Conclusions With this system, professionals have easy access to their occupational dosimetry records (including information on the workload) in the setting of their interventional departments, to thereby actively engage in the protection process.

Key concepts: Dosimeter, Lead apron, Dosimetry, Radiation protection, Medicine, Medical physics, Occupational exposure, Fluoroscopy