1994Zagazig Journal of Pharmaceutical Sciences/Zagazig Journal of Pharmaceutical ScienceOpen access

CHROMATOGRAPHIC ANALYSIS OF HUMAN SEMINAL ANGIOTENSIN I CONVERTING ENZYME ISOFORMS

Takamasa Yamaguchi, Ahmed M. Said

Open full text 0 citations

Abstract

Separation of isoforms of angiotensin I converting enzyme (EC 3.4.15.1, ACE) from human semen was attempted by chromatographic procedures. The crude ACE was fractionated on DEAE-Sephadex A-25 and Sephadex G-200 columns. Two ACE components were separated out in the first DEAE-SEphadex A-25 chromatography. The two ACE preparations (S-I and S-II) were separately applied to gel filtration through a Sephadex G-200 column. S-I was further separated into two peaks. Elution of the first peak showed MW about 150KD, while the second peak corresponded to MW about 100KD. S-II was eluted as a single Peak at an elution position corresponding to MW about 150 KD. At least three ACE components were separated out from the seminal extract.

Open-access reader

About this research paper

What this paper is about

Separation of isoforms of angiotensin I converting enzyme (EC 3.4.15.1, ACE) from human semen was attempted by chromatographic procedures. The crude ACE was fractionated on DEAE-Sephadex A-25 and Sephadex G-200 columns. Two ACE components were separated out in the first DEAE-SEphadex A-25 chromatography. The two ACE preparations (S-I and S-II) were separately applied to gel filtration through a Sephadex G-200 column. S-I was further separated into two peaks. Elution of the first peak showed MW about 150KD, while the second peak corresponded to MW about 100KD. S-II was eluted as a single Peak at an elution position corresponding to MW about 150 KD. At least three ACE components were separated out from the seminal extract.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Separation of isoforms of angiotensin I converting enzyme (EC 3.4.15.1, ACE) from human semen was attempted by chromatographic procedures. The crude ACE was fractionated on DEAE-Sephadex A-25 and Sephadex G-200 columns. Two ACE components were separated out in the first DEAE-SEphadex A-25 chromatography. The two ACE preparations (S-I and S-II) were separately applied to gel filtration through a Sephadex G-200 column. S-I was further separated into two peaks. Elution of the first peak showed MW about 150KD, while the second peak corresponded to MW about 100KD. S-II was eluted as a single Peak at an elution position corresponding to MW about 150 KD. At least three ACE components were separated out from the seminal extract.

Key concepts: Sephadex, Chromatography, Chemistry, Elution, Size-exclusion chromatography, Enzyme, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
CHROMATOGRAPHIC ANALYSIS OF HUMAN SEMINAL ANGIOTENSIN I CONVERTING ENZYME ISOFORMS — Research Paper | ScholarLens